BayTech MMP units controller Reset Procedures User Manual
Modular controller reset procedure
Modular Controller Reset Procedure
1), Remove the (5) screw from the
face plate,
Red Arrows
2),
Use EXTREME CAUTION: if
power is applied to unit, Pull
controller out to reveal the
connector,
Red
Arrow
.
Press the small tab in center of
connector to release the
connector from the circuit board.
Red
Arrow
Production Controller reset steps: This step will NOT affect the state of the outlets.
1. Use a paper clip or similar object, Press and hold a micro-switch in the hole next to the (SEL) button
under the LCD screen or between 2
nd
& 3
rd
LED (
BLUE Arrow
) disconnect the cable to the module for
5 seconds, (
RED Arrow
)
2. Continue to press micro-switch, connect cable to module, wait 10 seconds and release switch.
3. Serial in to the module. If it appears the controller did not reset, still contains old data, perform reset
again but increase the disconnect time to 10 seconds and wait time to 15 seconds.