Calibration

Sorensen Ethernet Option

4-8

M130/M131 Programming Manual

13. Enter the actual output current of the third calibration point:


CAL[n]:OUTP:CURR:FIVEPOINT 3

14. Program the output of the fourth calibration point by sending the following

command string from the computer:

CAL[n]:OUTP:CURR:DAC 45000

15. Let the output settle and measure the output current with the current shunt

and the high precision voltmeter; this is value 4.

16. Enter the actual output current of the fourth calibration point:


CAL[n]:OUTP:CURR:FIVEPOINT 4

17. Program the output of the fifth calibration point by sending the following

command string from the computer:

CAL[n]:OUTP:CURR:DAC 62250

18. Let the output settle and measure the output current with the current shunt

and the high precision voltmeter; this is value 5.

19. Enter the actual output current of the fifth calibration point:


CAL[n]:OUTP:CURR:FIVEPOINT 5

20. To review entered data for five–point current calibration, issue the following

query:

CAL[n]:OUTP:CURR:FIVEPOINT?

21. Program the supply to unlock the non-volatile memory for calibration value

storage:

CAL[n]:UNLOCK “6867”

22. Program the supply to store the calibration values in non-volatile memory:


CAL[n]:STORE

Allow 10 seconds for the non-volatile memory to be updated with the
new calibration values.

23. Program the supply to lock the non-volatile memory for calibration value

protection:

CAL[n]:LOCK

24. The output current calibration is complete. The unit may be turned off or other

calibration procedures may be performed.