Command

Description

SCPI

13) output voltage DAC gain
14) output voltage DAC offset
15) output current DAC gain
16) output current DAC offset
17) output voltage protection DAC gain
18) output voltage protection DAC offset
19) voltage measurement ADC gain
20) voltage measurement ADC offset
21) current measurement ADC gain
22) current measurement ADC offset
23) model string
24) OVP calibrated

Each value is separated by commas.

:REGister?

Returns the integer value of the status register.

N

:TIMeout?

Returns the integer value 1 (timeout since last
query) or 0 (no timeout) of the timeout status of
the channel.

N

:VOLTage

Sets the output voltage of the supply in volts
(default) or in millivolts. *See note on page 3-20.

C

[:LEVel]

Sets the output voltage of the supply in volts
(default) or in millivolts. *See note on page 3-20.

C

[:IMMediate]

Sets the output voltage of the supply in volts
(default) or in millivolts. *See note on page 3-20.

C

[:AMPLitude]

Sets the output voltage of the supply in volts
(default) or in millivolts. *See note on page 3-20.

C

:TRIGgered

Sets the value of the output voltage to be
implemented by the trigger. For DLM600 Series
firmware versions 1.07 and later, the polarity
relay must be in the correct position per the
algebraic sign of the voltage to be triggered. The
state of the polarity relay may be set using the
OUTP:POL <

NORM | INV

> command if it is not

already in the correct position. Do this before the
trigger command is issued.

For DLM600 Series firmware versions 1.06 and
earlier, the algebraic sign of the trigger voltage
determines the state of the polarity relay before
the voltage is triggered. Therefore, the user load
could be exposed to an unintended reverse
polarity voltage if the pre-trigger voltage had an
opposite algebraic sign from the trigger voltage.
For a pre-trigger voltage of zero, the above
consideration is not an issue.

C

:CLEar

Clears the trigger mode.