beautypg.com

5 troubleshooting, Resetting ip configuration, Cannot establish communication – AMETEK M130 User Manual

Page 47: Use rs232 port. note 19.2k baud rate at j6, Check ip address; validate your subnet mask, Lost/forgot password, Troubleshooting -29

background image

Sorensen Ethernet Option

Configuration

M130/M131 Programming Manual

2-29

2.4.5

T

ROUBLESHOOTING

Resetting IP Configuration

Either press and hold in the IP reset switch (S2) on the rear panel until the green
NET LED flashes (this could take 5 or more seconds), which resets the Primary
configuration to DHCP and AutoIP Enabled (and ignores Secondary
configuration), or send the SCPI command, SYST:NET:IP xxx.xxx.xxx.xxx
through one of the following: the RS-232, the Server, or VXI-11. This sets the
primary configuration to Static IP, and the secondary configuration is left where it
presently is.

Cannot Establish Communication

Use RS232 port. Note 19.2k baud rate at J6.

Query IP address with the SCPI command, SYST:NET:IP?

Query the MAC address with the SCPI command, SYST:NET:MAC?

For Slave (M131) communication issues, check the slave unit address switch
setting.

Communication Established, but No Power Supply Response

Check SCPI string for errors (use the command SYST:ERR? to check response
from unit)

Web Page Does Not Come Up

Check IP address; validate your SUBNET Mask.

Verify that both your computer and the power supply are on the same network.

If using a direct connection with a crossover cable, verify the PC is set to static
IP address on the same network.

Observe the indicator LED on Ethernet port (J11) for activity. The NET LED (at
rear panel center, near IP reset switch) will be lit when communication is
established.

Lost/Forgot Password

If you are a user, contact the Administrator of the power supply network to
modify your password.

If you are the administrator, the only way to recover is to press and hold the IP
reset switch on the rear panel until the Green NET LED blinks (this could take
five or more seconds). The administrator User Name and password will be
restored to factory defaults, as will the IP Address, the IP Addressing Mode, Ping
Enable, SUBNET Mask, Host name, and Description String. All other defined
user names and passwords are not affected by the reset operation.

This manual is related to the following products: