Sorensen Ethernet Option

IEEE 488.2 and SCPI Command Operation

M130/M131 Programming Manual

3-15

3.6 MEASURE

SCPI

C

OMMAND

S

UBSYSTEM

3.6.1

MEASURE

SCPI

C

OMMAND

S

UMMARY

MEASure[n]

:CURRent?

:CURRent

:AVErage

:AVErage?

:VOLTage?

: VOLTage

:AVErage

:AVErage?

3.6.2

MEASURE

SCPI

C

OMMAND

R

EFERENCE

Command

Description

SCPI

MEASure[n]

Measure subsystem. n = 1-31. The default channel
is 1.

C

:CURRent?

Returns the floating point value of the DC output
current in amps.

C

:CURRent

:AVErage

Enter a value of 1 to 5 to set the number of readings
to average together when returning the current
value from the MEAS:CURR? command. This
function reduces noise in the readback readings.
The (default) value of 1 provides the fastest
response time, but the noisiest readings. Available
for DLM600 Series firmware versions 1.08 and later.

:AVErage?

Returns the number 1 to 5 to indicate the last set
number of readings to average together when
taking a current reading. Available for DLM600
Series firmware versions 1.08 and later.

:VOLTage?

Returns the floating point value of the DC output
voltage in volts.

C

: VOLTage

:AVErage

Enter a value of 1 to 5 to set the number of readings
to average together when returning the voltage
value from the MEAS:VOLT? command. This
function reduces noise in the readback readings.
The (default) value of 1 provides the fastest
response time, but the noisiest readings. Available
for DLM600 Series firmware versions 1.08 and later.

:AVErage?

Returns the number 1 to 5 to indicate the last set
number of readings to average together when
taking a voltage reading. Available for DLM600
Series firmware versions 1.08 and later.