6 measure scpi command subsystem, 1 measure scpi command summary, 2 measure scpi command reference – AMETEK M130 User Manual
Page 65: Measure scpi command subsystem -15, Measure scpi command summary -15, Measure scpi command reference -15, 6 measure, Scpi

Sorensen Ethernet Option
IEEE 488.2 and SCPI Command Operation
M130/M131 Programming Manual
3-15
3.6 MEASURE
SCPI
C
OMMAND
S
UBSYSTEM
3.6.1
MEASURE
SCPI
C
OMMAND
S
UMMARY
MEASure[n]
:CURRent?
:CURRent
:AVErage
:AVErage?
:VOLTage?
: VOLTage
:AVErage
:AVErage?
3.6.2
MEASURE
SCPI
C
OMMAND
R
EFERENCE
Command
Description
SCPI
MEASure[n]
Measure subsystem. n = 1-31. The default channel
is 1.
C
:CURRent?
Returns the floating point value of the DC output
current in amps.
C
:CURRent
:AVErage
Enter a value of 1 to 5 to set the number of readings
to average together when returning the current
value from the MEAS:CURR? command. This
function reduces noise in the readback readings.
The (default) value of 1 provides the fastest
response time, but the noisiest readings. Available
for DLM600 Series firmware versions 1.08 and later.
—
:AVErage?
Returns the number 1 to 5 to indicate the last set
number of readings to average together when
taking a current reading. Available for DLM600
Series firmware versions 1.08 and later.
—
:VOLTage?
Returns the floating point value of the DC output
voltage in volts.
C
: VOLTage
:AVErage
Enter a value of 1 to 5 to set the number of readings
to average together when returning the voltage
value from the MEAS:VOLT? command. This
function reduces noise in the readback readings.
The (default) value of 1 provides the fastest
response time, but the noisiest readings. Available
for DLM600 Series firmware versions 1.08 and later.
—
:AVErage?
Returns the number 1 to 5 to indicate the last set
number of readings to average together when
taking a voltage reading. Available for DLM600
Series firmware versions 1.08 and later.
—