beautypg.com

5 readback resolution, 6 readback accuracy, Readback resolution -5 – AMETEK M130 User Manual

Page 17: Readback accuracy -5

background image

Sorensen Ethernet Option

Features, Functions and Specifications

M130/M131 Programming Manual

1-5

1.3.5

R

EADBACK

R

ESOLUTION

DLM600

DCS

Voltage

0.002% of full scale

0.02% of full scale

Current

0.002% of full scale

0.02% of full scale

1.3.6

R

EADBACK

A

CCURACY

DLM600

DCS

Voltage

± (0.1% of full scale output voltage)

± (0.1% + 0.15% of
maximum output voltage)

Current*

± (0.25% of full scale output current)

*

± (0.1% + 0.4% of
maximum output current)

*

After 30 minutes operation with fixed line, load, and temperature.

Note: Refer to the applicable power supply manual (DLM600 or DCS) for effects of

line regulation, load regulation, and temperature on accuracy specifications.