Safety characteristic data, Safe actuator with one encoder, Mttf >= 10 years – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual
Page 95: Mttf >= 57 years, 9technical details, 2 safety characteristic data, 1 safe actuator with one encoder

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
9-3
9.2
Safety characteristic data
9
Technical Details
9.2
Safety characteristic data
9200
Safety characteristic data
9-
9.2.1
Safe actuator with one encoder
Safe actuator with one encoder
9-
9.2.1.1
MTTF >= 10 years
MTTF >= 10 years
9-
SI_Kennzahlen_protego S1_ein_Geber_MTTF_10
SI_Kennzahlen_protego S_ein_Geber_MTTF_10_Einl
This operating mode requires a motor encoder with MTTF
≥
10 years.
SI_Kennzahlen_protego S_ein_Geber_MTTF_Allg
The motor encoder is already included in the characteristic data, so no
more calculations need to be performed for the "Safe Actuator" subsys-
tem.
SI_Kennzahlen_protego S1_ein_Geber_MTTF_10_Bild
SI_Kennzahlen_alle_Sicherheitsfunkt_protego S
The safety-related characteristic data is valid for all safety functions.
Si_Kennzahlen_Erläuterung_1
All the units used within a safety function must be considered when cal-
culating the safety characteristic data.
9.2.1.2
MTTF >= 57 years
MTTF >= 57 years
9-
SI_Kennzahlen_protego S_ein_Geber_MTTF_57
Safety characteristic data
Device
Operating mode
EN ISO 13849-1
PL
EN 954-1
Category
EN IEC 62061
SIL CL
PFH [1/h]
t
M
[year]
Safety card
Safe actuator
with motor en-
coder, MTTF of
motor encoder
≥
10 years
PL d
(Cat. 3)
Cat. 3
SIL CL 2
1.26E-07
20
Safety characteristic data
Device
Operating mode
EN ISO 13849-1
PL
EN 954-1
Category
EN IEC 62061
SIL CL
PFH [1/h]
t
M
[year]
Safety card
Safe actuator
with motor en-
coder, MTTF of
motor encoder
≥
57 years
PL e
(Cat. 4)
Cat. 4
SIL CL 3
2.37E-08
20
Subsystem
Safe actuator
PMCprotego D
PMCprotego S1
Motor encoder with MTTF ³ 10 years
- PMCprimo DriveP.01/AA0/5/0/0/208-480VAC PMCprimo DriveP.12/AA0/4/0/0/208-480VAC PMCprimo DriveP.12/AA0/4/P/0/208-480VAC PMCprimo DriveP.03/AA0/4/0/0/208-480VAC PMCprimo DriveP.06/AA0/4/0/0/208-480VAC PMCprimo DriveP.24/ABB/4/0/0/208-480VAC PMCprimo DriveP.03/AB0/5/0/0/208-480VAC PMCprimo DriveP.06/AB0/2/0/0/208-480VAC PMCprimo DriveP.03/AB0/3/0/0/208-480VAC PMCprimo DriveP.06/AB0/3/0/0/208-480VAC PMCprimo DriveP.12/AB0/2/0/0/208-480VAC PMCprimo DriveP.12/ABC/4/P/0/208-480VAC PMCprimo DriveP.12/AB0/3/0/0/208-480VAC PMCprimo DriveP.03/AB0/2/0/0/208-480VAC PMCprimo DriveP.12/AAC/4/0/0/208-480VAC PMCprimo DriveP.24/AA0/5/0/0/208-480VAC PMCprimo DriveP.12/AA0/2/0/0/208-480VAC PMCprotego D.01/000/0/0/2/208-480VAC PMCprotego D.03/000/0/0/2/208-480VAC PMCprotego D.06/000/0/0/2/208-480VAC PMCprotego D.12/000/0/0/2/208-480VAC PMCprotego D.24/000/0/0/2/208-480VAC PMCprotego D.12/000/0/P/2/208-480VAC PMCprotego D.72/000/0/0/2/208-480VAC PMCprotego D.24/000/0/P/2/208-480VAC PMCprotego D.48/000/0/0/2/208-480VAC PMCprotego D.01/200/0/0/2/208-480VAC PMCprotego D.01/100/0/0/2/208-480VAC PMCprotego D.01/010/0/0/2/208-480VAC PMCprotego D.06/010/0/0/2/208-480VAC PMCprotego D.06/100/0/0/2/208-480VAC PMCprotego D.06/200/0/0/2/208-480VAC PMCprotego D.03/010/0/0/2/208-480VAC PMCprotego D.03/200/0/0/2/208-480VAC PMCprotego D.03/100/0/0/2/208-480VAC PMCprotego D.12/010/0/0/2/208-480VAC PMCprotego D.24/200/0/P/2/208-480VAC PMCprotego D.12/200/0/0/2/208-480VAC PMCprotego D.12/100/0/0/2/208-480VAC PMCprotego D.12/010/0/P/2/208-480VAC PMCprotego D.12/200/0/P/2/208-480VAC PMCprotego D.24/100/0/P/2/208-480VAC PMCprotego D.24/010/0/P/2/208-480VAC PMCprotego D.12/100/0/P/2/208-480VAC PMCprotego D.24/200/0/0/2/208-480VAC PMCprotego D.24/100/0/0/2/208-480VAC PMCprotego D.24/010/0/0/2/208-480VAC PMCprotego S1 PMCprotego S2