beautypg.com

Digital outputs, Supply voltage, 6wiring – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual

Page 67: 5 digital outputs, 1 supply voltage

background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

6-5

6.5

Digital outputs

6

Wiring

6.5

Digital outputs

6500

Digital outputs

6-

6.5.1

Supply voltage

Supply voltage

6-

Verdr_DO_Versorgung

The digital outputs need a 24 VDC supply.

When selecting the power supply, please refer to the requirements
stated under “Technical Details”.

The power supply must be able to bridge a power outage of 20 ms.

Verdr_Versorgung_Warnung

Verdr_DO_24V_Versorg

Verdr_XGND_protego

WARNING!

Electric shock!
Safe electrical isolation must be ensured for the external power
supply that generates the supply voltage. Failure to do so could
result in electric shock. The power supplies must comply with
EN 60950-1, 05/2006, EN 61558-2-6, 11/1997.

Connector pin assignment

Connector X30

Pin

Name

Description

10

24 V Supply

Supply voltage for digital outputs (24 V)

21, 22

0 V Supply

Supply voltage for digital outputs (0 V)

Pins 21 and 22 are linked internally

Connection

Supply voltage

Max. cable length: 30 m

24 V connection isolated from exter-
nal power supply, e.g. with
isolating transformer

Noise suppression filter integrated
within the safety card

*) Please note the following

:

Link X30, Pin 21 or 22 to XGND on
the servo amplifier

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

X30

L3

10

X30

L1

L2

0 V

21, 22

+24 V

PE

+24 V

XGND

Servo Amplifier

*)

This manual is related to the following products: