8.1

Operating states

8

Operation

SS1

SS1 is activated
– After violation of the limit values
– After an error
– After a demand upon safety function SS1

Transition to STO: After activation of SS1 (drive is brought to a stand-
still with a defined braking ramp)

STO

There is no power to the motor after execution of safety function STO

Transition to CONFIG: Demand upon the Configurator

Transition to NORMAL OPERATION due to
– Reset of safety card (see "Recommissioning")
– Prior POWER ON