beautypg.com

Operating states, 8operation, 1 operating states – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual

Page 88

background image

8.1

Operating states

8

Operation

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

8-2

8.1

Operating states

8100

Operating states

8-

Betrieb_Zustaende

The safety card is always in clearly defined operating states.

POWER ON

The supply voltages are present.

Transition to STO once the supply voltages are applied

CONFIG

Download of configuration to the safety card

Transition to state of NORMAL OPERATION: Configuration down-
loaded without error

Transition to state of STO: Incorrect configuration data

The motor is switched volt free in the CONFIG operating state (STO is
active)

NORMAL OPERATION

No safety function activated

Transition to state of STO: Internal error

Transition to SAFE OPERATION: A safety function is activated

SAFE OPERATION

Safe operation after at least one safety function has been activated

Transition to STO: Internal error

Transition to SS1 due to
– Error
– Violation of limit values
– Demand upon safety function SS1

Transition to NORMAL OPERATION: No safety function activated

NORMAL

OPERATION

CONFIG

SAFE

OPERATION

SS1

STO

POWER ON

Download

configuration

Safety

function

deactivated

Safety

function

activated

Demand

upon

Configurator

Internal error

Error

STO

Limit values

Error

SS1 Activate

Error

Reset

This manual is related to the following products: