beautypg.com

7commissioning, 3 recommissioning – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual

Page 84

background image

7.3

Recommissioning

7

Commissioning

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

7-12

Procedure:

1. Switch off the 24 V supply to the servo amplifier.

2. Insert the SD card into the read device in the servo amplifier.

3. Keep both operator keys

on the servo amplifier pres-

sed down.

4. Switch on the 24 V supply to the servo amplifier.

5. Release the keys when "-" appears on the display.

6. Press both operator keys

again and then release

them.
– The firmware update for the servo amplifier is started.
– The file default.bin or default.s19 is loaded.
– Display: Counts from 0 to 100, stops at 100 and then counts from

100 to 0.

– The servo amplifier is restarted. The parameter file default.par is

loaded.

– The safety card is restarted: The "CONFIG" LED flashes.

7. Wait until "dis" (= drive integrated safety) appears on the display.

– Note: You must then press the left-hand operator key on the servo

amplifier within 60 seconds (see step 8).

8. Press the left-hand operator key

for at least 2 seconds.

– The configuration file default.pdis starts downloading to the safety

card. Display: "…".

– Once the configuration file has been downloaded, the safety card

starts up. The safety card is in "STARTUP" condition ("RUN" LED
flashes).

– If the download has been successful, the safety card switches to

"RUN" condition ("RUN" LED is lit).

This manual is related to the following products: