beautypg.com

Recommissioning after error, 7commissioning, 3 recommissioning – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual

Page 78: 2 recommissioning after error

background image

7.3

Recommissioning

7

Commissioning

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

7-6

Key

:

Servo amplifiers
– 24 V: Supply voltage
– BTB/RTO: Relay contact for operational readiness, servo amplifier
– L1, L2, L3: Mains voltage
– X8: Intermediate circuit
– STO-ENABLE: Start interlock
– HW-/SW-Enable: Hardware and software enable
– Enable U, V, W: Motor connection
– Motor n: Motor speed
– t

1

: Servo amplifier's run-up time

– t

2

: Load time, intermediate circuit capacitance

– t4: Processing time until servo amplifier is enabled

Safety card
– 24 V: Supply voltage
– SS1 Activate: SS1 activated
– SS1 SIL3/Reset: Input for SIL3 and reset
– Ready: Operational readiness
– STO Acknowledge: Status: STO activated
– t3: Safety card's run-up time

7.3.2

Recommissioning after error

Recommissioning after error

7-

Inbetrieb_Wiederinbetrieb_nach_Fehler

This section describes the recommissioning process after an error has
occurred.

Rectify the error, noting:

The error messages in the error stack

The LED display.

Betrieb_Neustart_nach_Fehler_S1

Perform a reset as follows:

Switch inputs "SS1 Activate" or "SS1 SIL3/Reset"

or

Run the command "CLRFAULT"

7.3.2.1

Switching the inputs "SS1 Activate" or "SS1 SIL3/Reset"

Switching the inputs "SS1 Activate" or "SS1 SIL3/Reset"

7-

Betrieb_Neustart_S1

1. Switch input "SS1 Activate" or "SS1 SIL3/Reset" to 0 V

The safety card performs the safety function SS1 (Safe Stop 1) and
switches to a "STOP" condition. The "FAULT" LED flashes.

This manual is related to the following products: