Reset, restart, start and stop options, Overview, Cold start, "startup – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual
Page 63: 8operation, 2 reset, restart, start and stop options, 1 overview, 2 cold start, "startup

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
8-7
8.2
Reset, restart, start and stop options
8
Operation
8.2
Reset, restart, start and stop options
8200
Reset, restart, start and stop options
8-
8.2.1
Overview
Overview
8-
Reset_Uebersicht_primo_C
Various options are available to specifically stop or start the motion con-
troller, for operation or commissioning for example. The implications of
intervening depend on the specific command that is used.
The following table provides an overview of the impact of a reset, start
or stop on a variable.
x = Value is retained, - = Value is re-initialised
8.2.2
Cold start, "Startup"
Cold start, "Startup"
8-
Reset_Power_Off
A reset via the "Power Off" operating status performs a system cold start
with "Startup".
Switch the 24 VDC supply voltage to the motion controller off and
then on again.
The motion controller changes to "Startup" operating status.
Options
Action
Command language
IEC 61131 programming
Cold start motion controller
Cold start (HW reset)
RS1 (alternative: Hold down
reset button for long period
(> 4 s))
Stop user program
Stop
RS3 (alternative: Hold down
reset button for short period
(< 4 s))
Online --> Stop
Start user program
Start
RS2 (alternative: Hold down
reset button for short period
(< 4 s))
Online --> Start
Reset motion controller
Cold reset
RS5
Online --> Reset (cold)
Warm reset
RS4
Online --> Reset
Original reset
RS6
Online --> Reset (original)
Action
Variable with at-
tribute RETAIN
Variable with at-
tribute PER-
SISTENT
Variable with at-
tribute
RETAIN PER-
SISTENT
Warm reset
x
-
x
Cold reset
-
-
-
Original reset
-
-
-
- PMCprimo DriveP.01/AA0/5/0/0/208-480VAC PMCprimo DriveP.12/AA0/4/0/0/208-480VAC PMCprimo DriveP.12/AA0/4/P/0/208-480VAC PMCprimo DriveP.03/AA0/4/0/0/208-480VAC PMCprimo DriveP.06/AA0/4/0/0/208-480VAC PMCprimo DriveP.24/ABB/4/0/0/208-480VAC PMCprimo DriveP.03/AB0/5/0/0/208-480VAC PMCprimo DriveP.06/AB0/2/0/0/208-480VAC PMCprimo DriveP.03/AB0/3/0/0/208-480VAC PMCprimo DriveP.06/AB0/3/0/0/208-480VAC PMCprimo DriveP.12/AB0/2/0/0/208-480VAC PMCprimo DriveP.12/ABC/4/P/0/208-480VAC PMCprimo DriveP.12/AB0/3/0/0/208-480VAC PMCprimo DriveP.03/AB0/2/0/0/208-480VAC PMCprimo DriveP.12/AAC/4/0/0/208-480VAC PMCprimo DriveP.24/AA0/5/0/0/208-480VAC PMCprimo DriveP.12/AA0/2/0/0/208-480VAC PMCprimo C.0/A/A/2 PMCprimo C.0/A/B/2 PMCprimo C.0/A/B/5 PMCprimo C.0/A/B/7 PMCprimo C.0/A/B/3 PMCprimo C.0/A/B/6 PMCprimo C.0/A/A/7 PMCprimo C.0/A/A/3 PMCprimo C.0/A/A/4 PMCprimo C.0/A/A/5 PMCprimo C.0/A/A/6 PMCprimo C.0/A/B/4 PMCprotego D.01/000/0/0/2/208-480VAC PMCprotego D.03/000/0/0/2/208-480VAC PMCprotego D.06/000/0/0/2/208-480VAC PMCprotego D.12/000/0/0/2/208-480VAC PMCprotego D.24/000/0/0/2/208-480VAC PMCprotego D.12/000/0/P/2/208-480VAC PMCprotego D.01/200/0/0/2/208-480VAC PMCprotego D.01/100/0/0/2/208-480VAC PMCprotego D.01/010/0/0/2/208-480VAC PMCprotego D.06/010/0/0/2/208-480VAC PMCprotego D.06/100/0/0/2/208-480VAC PMCprotego D.06/200/0/0/2/208-480VAC PMCprotego D.03/010/0/0/2/208-480VAC PMCprotego D.03/200/0/0/2/208-480VAC PMCprotego D.03/100/0/0/2/208-480VAC PMCprotego D.12/010/0/0/2/208-480VAC PMCprotego D.12/200/0/0/2/208-480VAC PMCprotego D.12/100/0/0/2/208-480VAC PMCprotego D.12/010/0/P/2/208-480VAC PMCprotego D.12/200/0/P/2/208-480VAC PMCprotego D.12/100/0/P/2/208-480VAC PMCprotego D.24/200/0/0/2/208-480VAC PMCprotego D.24/100/0/0/2/208-480VAC PMCprotego D.24/010/0/0/2/208-480VAC