beautypg.com

8operation, 1 operating states and changes in operating status – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual

Page 62

background image

8.1

Operating states and changes in operating status

8

Operation

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

8-6

-->

Change from "STOP" to "RUN"

The system performs this status change after

Running the command RS2 in the terminal program PTerm (change

to "RUN").

Running commands in the IEC 61131 development environment:

Holding down the reset button for a short period (< 4 s) (alternative to

RS2 command (change to "RUN")).

-->

Change from "STOP" to "Fatal Error"

The system changes to "Fatal Error" status if an error occurred in

"STOP" status.

Remedy

Delete user program

Firmware update

-->

Change from "Fatal Error" to "Startup"

"Fatal Error" operating status is only adopted temporarily after an error

has occurred. The motion controller automatically changes to "Startup"

operating status.

The error is entered in the error stack.

4

3

4

5

5

1

This manual is related to the following products: