Page 60: 3 change in operating status

8.1
Operating states and changes in operating status
8
Operation
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
8-4
8.1.3
Change in operating status
Change in operating status
8-
Betriebszustandswechsel_primo_C
-->
All operating states change to "Power Off"
The system changes to "Power Off" operating status when the 24 VDC
supply voltage has been switched off.
-->
Change from "Power Off" to "Startup"
The system changes to "Startup" operating status when the 24 VDC
supply voltage has been switched on.
-->
Change from "Startup" to "Boot Menu"
The LED lights for 4 s if "Startup" has been run without error.
Press the reset button during this time to change to "Boot Menu" op-
erating status.
-->
Change from "Startup" to "RUN"
"Startup" operating status has been run without error. The system
changes to "RUN" status if a user program was loaded in "Startup" sta-
tus.
-->
Change from "Startup" to "STOP"
"Startup" operating status has been run without error. The system
changes to "STOP" status if no user program was loaded in "Startup"
status.
-->
Change from "Startup" to "Fatal Error"
The system changes to "Fatal Error" status if an error occurred in "Star-
tup" status.
1
0
1
1
2
1
3
1
4
1
5
- PMCprimo DriveP.01/AA0/5/0/0/208-480VAC PMCprimo DriveP.12/AA0/4/0/0/208-480VAC PMCprimo DriveP.12/AA0/4/P/0/208-480VAC PMCprimo DriveP.03/AA0/4/0/0/208-480VAC PMCprimo DriveP.06/AA0/4/0/0/208-480VAC PMCprimo DriveP.24/ABB/4/0/0/208-480VAC PMCprimo DriveP.03/AB0/5/0/0/208-480VAC PMCprimo DriveP.06/AB0/2/0/0/208-480VAC PMCprimo DriveP.03/AB0/3/0/0/208-480VAC PMCprimo DriveP.06/AB0/3/0/0/208-480VAC PMCprimo DriveP.12/AB0/2/0/0/208-480VAC PMCprimo DriveP.12/ABC/4/P/0/208-480VAC PMCprimo DriveP.12/AB0/3/0/0/208-480VAC PMCprimo DriveP.03/AB0/2/0/0/208-480VAC PMCprimo DriveP.12/AAC/4/0/0/208-480VAC PMCprimo DriveP.24/AA0/5/0/0/208-480VAC PMCprimo DriveP.12/AA0/2/0/0/208-480VAC PMCprimo C.0/A/A/2 PMCprimo C.0/A/B/2 PMCprimo C.0/A/B/5 PMCprimo C.0/A/B/7 PMCprimo C.0/A/B/3 PMCprimo C.0/A/B/6 PMCprimo C.0/A/A/7 PMCprimo C.0/A/A/3 PMCprimo C.0/A/A/4 PMCprimo C.0/A/A/5 PMCprimo C.0/A/A/6 PMCprimo C.0/A/B/4 PMCprotego D.01/000/0/0/2/208-480VAC PMCprotego D.03/000/0/0/2/208-480VAC PMCprotego D.06/000/0/0/2/208-480VAC PMCprotego D.12/000/0/0/2/208-480VAC PMCprotego D.24/000/0/0/2/208-480VAC PMCprotego D.12/000/0/P/2/208-480VAC PMCprotego D.01/200/0/0/2/208-480VAC PMCprotego D.01/100/0/0/2/208-480VAC PMCprotego D.01/010/0/0/2/208-480VAC PMCprotego D.06/010/0/0/2/208-480VAC PMCprotego D.06/100/0/0/2/208-480VAC PMCprotego D.06/200/0/0/2/208-480VAC PMCprotego D.03/010/0/0/2/208-480VAC PMCprotego D.03/200/0/0/2/208-480VAC PMCprotego D.03/100/0/0/2/208-480VAC PMCprotego D.12/010/0/0/2/208-480VAC PMCprotego D.12/200/0/0/2/208-480VAC PMCprotego D.12/100/0/0/2/208-480VAC PMCprotego D.12/010/0/P/2/208-480VAC PMCprotego D.12/200/0/P/2/208-480VAC PMCprotego D.12/100/0/P/2/208-480VAC PMCprotego D.24/200/0/0/2/208-480VAC PMCprotego D.24/100/0/0/2/208-480VAC PMCprotego D.24/010/0/0/2/208-480VAC