Please note:

Cable cross sections for field connection terminals in mm

2

:

– Digital inputs/outputs, supply voltage: 0.5 (AWG20) ... 1.0

(AWG18), AEH without plastic collar, in accordance with DIN

46228/1

Verdr_Allgemein

Inputs

Appropriate wiring must be used to exclude short circuits between

the inputs or to a supply line!

Cables must be shielded if the signals are used as reference inputs.

Other signal lines do not need to be shielded.

Outputs

If short circuits occur between the cable from the output to the load

and a supply line, it will no longer be possible to switch off the load.

Possible remedy: Use separate multicore cable for supply voltages.

Use appropriate wiring to exclude short circuits between the outputs!

The actuators may be connected using unshielded cables.

The outputs do not need suppression for inductive loads.

Cable material

Use copper wiring.