102
MotionCreatorPro
Right play button: Clicking this button will cause the 8102 start
to outlet pulses according to previous setting.
Z
In “Absolute Mode,” it causes the axis to move to posi-
tion.
Z
In “Relative Mode,” it causes the axis to move back-
wards.
Z
In “Cont. Move,” it causes the axis to start to move
according to the velocity setting, but in the opposite
direction.
Z
In “Manual Pulser Move,” it causes the axis to go into
pulse move. The speed limit is the value set by “Maxi-
mum Velocity.”
18.Stop Button: Clicking this button will cause the 8102 to
decelerate and stop. The deceleration time is defined in
“Decel. Time.” The related function is _8102_sd_stop().
19.I/O Status: The status of motion I/O. Light-On means
Active, while Light-Off indicates inactive. The related
function is _8102_get_io_status().
20. Buttons:
Z
Next Card: Change operating card.
Z
Next Axis: Change operating axis.
Z
Save Config: Save current configuration to 8102.ini And
8102MC.ini.
Z
Close: Close the menu.
21.P2 Additional I/O: Control and respond digital I/O on P2
connector. The related functions are:
Z
_8102_set_gpio_output2 (), _8102_get_gpio_output2 (),
Z
_8102_get_gpio_input2 ()