beautypg.com

14 area account number messages – DMP Electronics DMP Command Processor Panel XR500 User Manual

Page 82

background image

XR500 Series Canadian Programming Guide

Digital Monitoring Products

73

APPENDIX

23.13 Common Keypad Messages

There are several common keypad messages that the keypad displays to inform the technician and

end-user. The common messages are described below. Possible solutions are also provided.

Message

Meaning

Possible Solutions

INVALID AREA

The user has attempted a door access for an

area they are not assigned.

Change the user access areas if access to

the area is needed. If access is not needed,

the user cannot enter the area.

INVALID CODE

The user code you entered is not recognized

by the system.

Check the user code and try again.

INVALID PROFILE

A user attempted a function that is outside of

the assigned profile.

Check the user profile settings.

INVALID TIME

A user code assigned to a specific schedule has

entered outside of the valid schedule.

See Schedules and User Codes.

ENTER 2ND CODE

The area you are attempting to disarm or

access is a Two Man Area.

A second and different user code must be

entered.

CLOSING TIME

The scheduled has expired but the area is not

armed.

Users still on the premise should arm the

system or extend the schedule to a later

time.

LATE TO CLOSE

The system was not armed at its scheduled

closing time.

Users still on the premise should arm the

system or extend the schedule to a later

time.

FAILED TO EXIT

A user assigned the anti-passback option has

attempted to re-enter an area from which they

did not exit properly.

The user must exit the area through the

proper door. If not possible, your system

administrator should select the Forgive

option in the User Codes menu.

AC TROUBLE

The system is not getting proper power.

Check that all AC connections are good.

BATTERY TROUBLE

The battery is either low or missing.

Check that the battery connections are good

and the battery is still good.

PHONE LINE 1

TROUBLE

There is trouble with the phone line

supervision.

Plug in the phone line.

SYSTEM TROUBLE or

SERVICE REQUIRED

There is a problem with one or more

components in the system.

Make sure the J16 jumper is removed from

the panel. Make sure there is not a short or

open condition on the green data wire to the

keypad. You may also need to check that all

of the keypads and expansion modules on

the bus are good.

SYSTEM BUSY

The system is performing another task with a

higher priority.

Wait a few moments for the system to

complete the task. Make sure the J16

jumper is not on the panel. If the message

displays for a long period of time, the

processor could be locked up.

4-WIRE BUS TROUBLE

There is not a supervised device on the bus.

Program a device to be supervised.

There is low voltage or an open yellow wire.

Make sure all wires are connected.

Two devices share the same address.

Program one of the devices to a unique

address.

TRANSMIT FAIL

The panel has attempted to communicate

with the central station 10 times and has not

succeeded.

Verify your communication type, account

number, and phone number. Make sure the

telephone line is connected and working

properly.

NON-POLLED

ADDRESS

The device is not set to DOOR, KEYPAD or

FIRE in Device Setup during programming.

Program the device as DOOR, KEYPAD or

FIRE in Device Setup.

ENTER CODE (to

enter Programming)

A lockout code has been programmed for the

panel.

Enter the lockout code.

WIRELESS TROUBLE

The panel is unable to communicate with the

wireless receiver.

Verify the receiver is properly connected to

the panel. Verify the correct House Code is

programmed in System Options.

The wireless receiver is missing.