23.12 Zone Type Specifications
The XR500 Series Canadian panel contains multiple default zone types for use in configuring the system.
These zone types provide the most commonly selected functions for their applications. All zone types
can be customized by changing the variable options listed below. The Keypad Bus Zone Information table
below reflects the zone types for Keypad Bus Zones. The XR500 Series LX-Bus Zone Information table on
the next page reflects the zone types for LX-Bus Zones.
Keypad Bus Zone
Information
Type
Area Fire
Bell
Disarmed
Open
Disarmed
Short
Armed
Open
Armed
Short
Swinger
Pr
ew
arn
Entry Dela
y
Retar
d Dela
y
Pr
esignal
Fast R
esponse
Cr
oss Z
one
Priori
ty
Fol
low Ar
ea
Real-
Time Rprts
Door Number
St
yle
Assign Disarm condition of
NT, DY, EX, A1, and A2 only
Assign Prewarn and Entry
Delay for EX only
Assign Retard and Presignal
for FI, SV, A1, and A2 only
Zone Type Defaults
--
DY
FI
EM
A1
FV
NT
EX
PN
SV
A2
AR
INT
PERIM
BDRM
or
1
to
32
Output
*
Message
Output
*
Action
Message
Output
*
Action
Message
Output
*
Action
Message
Output
*
Action
A
T
L
-
D
S
C
S
P
M
F
A
T
L
-
D
S
C
S
P
M
F
A
T
L
-
D
S
C
S
P
M
F
A
T
L
-
D
S
C
S
P
M
F
N
or
Y
1
to
16
1
or
4
N
or
Y
1
to
16
N
or
Y
N
or
Y
N
or
Y
0
to
16
N
or
Y
0
to
16
TGL
ARM
DIS
STEP
MNT
Night
NT
-
0
S
-
0
S
A
0
S
A
0
S Y
N N N 0 N 0
Day
DY
T
0
S
T
0
S
A
0
S
A
0
S Y
N N N 0 N 0
Exit
EX
-
0
S
-
0
S
A
0
S
A
0
S Y
1-16
1
N N N
N 0
Fire
FI
0
T
0
S
A
0
S N
N + N N N
Panic
PN
T
0
S
A
0
S N
N N N
Emergency
EM
T
0
S
A
0
S N
N N N
Supervisory
SV
0
T
0
S
A
0
S N
N + N N N
Auxiliary 1
A1
T
0
S
A
0
S
T
0
S
A
0
S N
N + N N N 0 N 0
Auxiliary 2
A2
T
0
S
A
0
S
T
0
S
A
0
S N
N + N N N 0 N 0
Fire Verify
FV
0
T
0
S
A
0
S N
N
N
Arming
AR
TGL
*Output Options: 1 to 6, 450 to 474, 480 to 499, 500 to 999, D1 to D16, G1 to G20. + = Set retard to YES before selecting presignal. = Zone functions not available.
23.12.1 Keypad Bus Zone Type Defaults
These are complete spellings of the abbreviations used for the zone types, such as Night and Exit.
Type - These are the abbreviations used for the zone types, such as NT and EX.
Area - For an Area or Home/Sleep/Away with Guest system this is 1 to 32. For an All/Perimeter or Home/
Sleep/Away system, this is the Interior, Bedroom, or Perimeter. Select the area for NT, DY, EX, A1, A2, and
AR types.
Fire Bell Out - Only available for FI, FV, and SV zones. Use any output zone number listed.
Message - A = alarm report, T = trouble report, L = local, no report, — (dash) = no report, D = door propped
(When SV zone is connected to 303 Silence/Reset Switch), S = sensor reset/alarm silence,
C = early morning ambush cancel.
Output - These are 1 to 6 on-board and 500 to 999 off-board relay outputs, 450 to 474 and 480 to 499
wireless outputs, D1 to D16, and G1 to G20.
Action - This selects the action of the output: S = steady, P = pulse, M = momentary, and F = follow
Swinger - The zone can be automatically bypassed after a programmed number of trips.
Prewarn - This selects the keypad address that sounds the entry prewarn for this zone.
Entry Delay - This is the entry delay timer selected as the default for this zone.
Retard Delay - Provides a programmed retard time before an alarm initiates from a shorted zone. When
used on an arming zone, the retard delay occurs when the zone is shorted before the armed state has
changed. If the arming zone has Maintain as the Style, the retard delay also occurs when the zone returns
to a normal state.
Presignal - Provides a keypad tone for zones in retard delay. Retard must be YES before Presignal can be
selected.
Fast Response - Provides a 167ms zone response instead of the normal 500ms response.
Cross Zone - Provides cross zoning with any of the 574 zones.
Priority - Requires this zone to be in a normal condition before the area can be armed.
Style - The abbreviations for arming zone style:
TGL = Toggle, ARM = Arm only, DIS = Disarm only, STEP = Wireless arming, MNT = Maintain