3  user code position, 4  user code length, 9  require site code – DMP Electronics DMP Command Processor Panel XR500 User Manual
Page 30: 9 .1  site code display, 10  number of user code digits, 11 degraded mode, 11 user code position, 12 user code length, 13 require site code, 1 site code display
XR500 Series Canadian Programming Guide
Digital Monitoring Products
21
DEVICE SETUP
734 Site Code Programming
6.18.9
Site Code Position
Enter the site code start position in the data string. Press any top row Select
key to enter a number between 1-255. Default is 1.
6.18.10
Site Code Length
Enter the number of characters the site code contains. Press any top row
Select key to enter a number between 1-16. Default is 8.
6.18.11
USER CODE
POSITION: 9
User Code Position
Define the User Code start bit position. Press any top row Select key to
enter a number between 0-255. Default is 9.
6.18.12
USER CODE
LENGTH: 16
User Code Length
Define the number of User Code bits. Press any top row Select key to enter
a custom number. Custom numbers can only be a number between 16-32.
On a 734N/734N-WiFi Module, custom numbers can be between 1-255.
The default is 16.
6.18.13
REQUIRE SITE
CODE?
NO YES
Require Site Code
Press the top row Select key under YES to use a site code.
In addition to User Code verification, door access is only granted when any one site
code programmed at the SITE CODE ENTRY option matches the site code received in
the Wiegand string.
6.18.13 .1
SITE CODE 1: -
Site Code Display
734 Module: You can program up to 8 three-digit site codes. Site code
range is 0-999. Any previously programmed site codes display. Dashes
represent blank site codes. Default is blank.
Note: A card with a site code greater than three digits cannot be used.
Use only cards with three-digit site codes.
734N/734N-WiFi Module: You can program up to 8 five-digit site codes. Site
code range is 1-65535. Any previously programmed site codes display. Site
Code 1 defaults to 127. Site Codes 2-8 default to blank. Dashes represent
blank site codes.
Site Code 1 displays first. Enter a site code number followed by the
Command key to advance to the next prompt, Site Code 2. To delete an
existing site code, press any Select key. Either enter a new site code
followed by Command, or press Command to leave blank and continue to
the next site code. Repeat these steps to change, delete, or add up to 8 site
codes
.
6.18.14
NO OF USER CODE
DIGITS: 5
Number of User Code Digits
The 734 module recognizes user codes from 4-10 digits in length. The 734N
/
734N-WiFi
module recognizes user codes from 1-10 digits in length.
Press any top row Select key
to enter a user code digit length between 4-10 digits. This number must match the
user code number length being used by the panel. Default is 5. For an XR500 Area
System, use 4 to 10 digits (typically 5). For all other systems and panels, use 4 digits.
Any selection above 5 digits require entry of the custom card definitions with custom
site and user code positions for the Wiegand string. When searching the bit string
for the user code, the digits are identified and read from left to right.
SITE CODE
POSITION: 1
SITE CODE
LENGTH: 8
SITE CODE 1:
(1-65,535) 127
0 1 1 1 0 1 0 1 1 0 1 1 0 1 0 1 0 0 0 1 1 0 0 1 1 1
First Bit
Received
Position = 0
Site Code
Position = 1
Length = 8
User Code
Position = 9
Length = 16
Last Bit
Received
Position = 25
In this example the Wiegand Code Length = 26 bits.