beautypg.com

19  wireless audible annunciation, 20  enable keypad panic keys, 21  occupied premises – DMP Electronics DMP Command Processor Panel XR500 User Manual

Page 40: 22  enhanced zone test, 23 dual eol, 24  send 16 character names, Wireless audible annunciation, Enable keypad panic keys, Occupied premises, Enhanced zone test

background image

XR500 Series Canadian Programming Guide

Digital Monitoring Products

31

SYSTEM OPTIONS

9.22

ENHANCED ZONE

TEST: NO YES

Enhanced Zone Test

Select YES to allow enhanced zone test operation. The default is NO.
Enhanced operation allows:

• Panic Test and Walk Test functions can be restricted to operate only during an

Area 32, Shift 4 schedule if programmed. If no schedule is entered, the walk

test always operates.

• A Verify message is sent each time a zone is tested. If a zone is tripped

multiple times, a Verify message is sent for each trip. This allows the Central

Station to record the number of devices per zone.

• The Verify message for each zone test is sent at the time the trip occurs

instead of at the end of Walk Test.

• The System Test Begin and System Test End Central Station messages indicate

the type of zone being tested. The System Test Begin message also includes

the user name and number.

9.23

Dual EOL

Select YES to enable the use of dual 1K EOL resistors on panel zones one to eight.

This zone operation is used for medium or high risk ULC Listed applications. Select

NO to disable this feature. Default is YES.
Note: If using a 714, 714-8, or 714-16 for dual zone protection, program two zones

as the same name or equivalent and connect to the contact in the protected area.

Refer to the Dual Zone Protection diagram in the XR500 Series Canadian Installation

Guide for complete details.

9.24

SEND 16 CHAR

NAMES: NO YES

Send 16 Character Names

This option allows central stations to select being sent either the first 16 characters

of the name field or the entire programmed name, up to 32 characters, for user

name, user profile, zone name, area name, output name, and group name.
Select YES to have the first 16 characters of the name field sent to the central

station. Select NO to send the exact number of characters entered in the name field

from 1 up to the maximum of 32 characters. Default is YES.
Note: Using 32 character names increases the length of the DMP Serial 3 message

from the panel to the receiver. The SCS-1R receiver does not require an update to

pass these messages to the Host Automation System of the Central Station. Before

using names longer than 16 characters, determine whether the Host Automation

System of your Central Station can accept 17 to 32 character names. If not, only use

16 character names.

9.25

KEYPAD ARMED LED

ALL

Keypad Armed LED

This option displays only when using an Area system. Press any top row key to select

the operation of the Armed LED on the keypad. Select ALL to require all keypad

display areas to be armed before the keypad Armed LED turns on. Select ANY to turn

on the keypad Armed LED when any keypad display area is armed. Default is ALL.

9.26

USE FALSE ALARM

QUESTION NO YES

Use False Alarm Question

Select YES to display IS THIS A FALSE ALARM? NO YES at the keypad in place of

CANCEL VERIFY when a burglar alarm occurs. This operates for ALL/PERIM and

HOME/SLEEP/AWAY arming systems. Default is NO.

9.26

ALLOW OWN USER

CODE CHG? NO YES

Allow Own User Code Change

This option allows users without user code authority to change their own user code.

When YES is selected, the User Code menu displays USER CODE: ***** at the keypad to

allow that user to change their own code. If NO is selected, the user cannot change their
personal user code. Default is NO.

KEYPAD ARMED LED

ALL ANY

DUAL EOL NO YES