Printer reports, 1  printer reports, 2  arm and disarm reports – DMP Electronics DMP Command Processor Panel XR500 User Manual
Page 50: 3  zone reports, 4  user command reports, 5  door access reports, 6  supervisory reports, Arm and disarm reports, Zone reports, User command reports
XR500 Series Canadian Programming Guide
Digital Monitoring Products
41
STATUS LIST
15.5
BURGLARY ZONES:
Burglary Zones
Specifies the keypad addresses (1 through 16) where all burglary zone alarms and
troubles display. Bur glary zones in clude Night, Day, and Exit type zones. Burglary
zone troubles remain in the list until the zone restores. All keypads are selected by
default.
For zone alarms, only the last burglary zone tripped re mains in the list. The alarm
re mains in the list un til another burglary zone goes into alarm, any area of the
system is dis armed, or 10 minutes elapse without an alarm. This ensures that if a
bur glary is in progress the last zone tripped remains in the list even if the zone is
restored.
The keypad buzzer sounds for one second on bur glary alarms.
When using LCD Keypads, the panel provides distinct speaker tones from the keypad
for Burglary:
On - Burglary zone alarm and Bell Output or Burglary Bell Output is ON.
Off - Alarm Silence.
You can further define which keypad address shows a Burglary Zone event by
entering that area number in the Display Areas menu during Device Setup.
15.6
SPRVISORY ZONES:
Supervisory Zones
Specifies the keypad addresses (1 through 16) where all su pervisory zone alarms
and troubles display. Supervisory zones are entered in the sta tus list and sound the
keypad buzzer until a valid user code is entered at any keypad address. If a trouble
condition remains in the display, the buzzer sounds at 10:00 am daily until the
supervisory trouble is cleared from the Status List.
15.7
PANIC ZONES:
Panic Zones
Specifies the keypad addresses (1 through 16) where all panic zone alarms and
troubles display. The name of the zone remains in the list until the zone re stores.
The keypad buzzer does not sound for panic alarms or troubles.
15.8
EMERGENCY ZONES:
Emergency Zones
Specifies the keypad addresses (1 through 16) where all emer gency zone alarms and
troubles display. The name of the zone remains in the list until the zone re stores.
The keypad buzzer does not sound for emer gency alarms or troubles.
15.9
AUX 1 ZONES:
Auxiliary 1 Zones
Specifies the keypad addresses (1 through 16) where all Aux iliary 1 zone alarms and
troubles display. The name of the zone remains in the list until the zone restores.
The keypad buzzer does not sound for Auxiliary 1 alarms or troubles.
You can further define which keypad address shows an Auxiliary 1 Zone event by
entering that area number in the Display Areas menu during Device Setup.
15.10
AUX 2 ZONES:
Auxiliary 2 Zones
Specifies the keypad addresses (1 through 16) where all Aux iliary 2 zone alarms and
troubles display. The name of the zone remains in the list until the zone restores.
The keypad buzzer does not sound for Auxiliary 2 alarms or troubles.
You can further define which keypad address shows an Auxiliary 2 Zone event by
entering that area number in the Display Areas menu during Device Setup.
15.11
COMM PATH TRBL:
ALL NO YES
Communication Trouble
Specifies when communication troubles are displayed on keypads that are
programmed to display System Monitor Troubles. Default is NO.
Select YES to display communication trouble when any communication path fails.
Select ALL to display communication trouble only when all paths have failed.