XR500 Series Canadian Programming Guide
38
OUTPUT GROUPS
Output Groups
13.1
OUTPUT GROUPS
Output Groups
This function allows you to assign outputs to groups. Output groups can be assigned
to other areas of programming such as Output Options or Alarm Action of Zone
Information, just like single outputs are assigned. This allows the entire group of
outputs to turn on and off as required by the programming option.
13.2
GROUP NO: -
Group Number
Enter a group number from 1 to 20. Up to 20 different groups may be assigned.
13.3
GROUP NAME X X
Group Name
The group name displays. To change the default name, press any top row Select key
then enter up to 32 characters for the group name. Press COMMAND to enter the
outputs to be assigned to the group.
13.4
OUTPUT NO 1:
0
OUTPUT NO 2:
0
OUTPUT NO 4:
0
OUTPUT NO 5:
0
OUTPUT NO 3:
0
OUTPUT NO 7:
0
OUTPUT NO 8:
0
OUTPUT NO 6:
0
Output Number
Enter the Output number. Entry range is 1 to 6, 450 to 474, 480 to 499, 500 to 999
(outputs), D1 to D16 (doors), and G1 to G20 (groups). The maximum number of
outputs that can be assigned to a specific group is eight.
An output group may be assigned as one of the output numbers in another output
group.
Example: Output Group 1 consists of only four assigned outputs. Output Group
1 could be assigned as one output in Output Group 2. Output Group 2 could still
have 7 other outputs assigned to that group. When Output Group 2 is turned on, 11
outputs could be turned on. This allows Output Groups to be assigned within other
Output Groups providing many combinations.
Output groups 1 to 10 can be assigned by a user profile for applications such as
elevator control. See the XR500 User’s Guide (LT-0683CAN) Output Group section for
additional information.
Output groups 11 to 20 cannot be assigned to a profile and are available for
installation applications such as special lighting, etc. To assign these groups to a
profile, use Remote Link™ or System Link™ software from DMP.