Page 71: 2 diagnostics function, False alarm reduction, Diagnostics function, Feature upgrade
Digital Monitoring Products
XR500 Series Canadian Programming Guide
62
FEATURE UPGRADE
Feature Upgrade
22.1
FEATURE UPGRADE
Feature Upgrade
In the Programming Menu, pressing COMMAND at the SET LOCKOUT CODE prompt
displays FEATURE UPGRADE. This allows you to enable additional features in the
panel. Press any top row Select key to display the first available feature. ENABLED
or DISABLED displays indicating whether this feature is currently used in this panel.
Press the COMMAND key to display additional feature(s).
ENTER KEY
-
To enable a feature, press any top row Select key anywhere in the features list to
display the ENTER KEY prompt.
Enter the factory-supplied feature key for the specific panel and press the COMMAND
key. The feature specific to the key displays as ENABLED.
Note: XR500 Series version 106 or higher panels require a six (6) character feature
key. Version 105 panels require a 16-character feature key.
If the feature key entered is not accepted, the ENTER KEY prompt displays again.
Re-enter the feature key and press the COMMAND key.
22.1.1
ENCRYPTION
DISABLED
Encryption
Enable this feature to provide 128 bit AES data encryption. This feature upgrade
can only be enabled on an XR500N panel version 105 or higher. For installations
where an XR500 panel is installed, it is recommended the XR500 be replaced with an
XR500E panel.
To complete encryption installation, access System Status in the User Menu to verify
the encryption status (ON or OFF). If the status displays OFF, it indicates that the
Passphrase has not been entered and data transmissions are not encrypted. See
Network Options to set up a Passphrase.
22.1.2
ALL NO YES OPTN
DISABLED
All No Yes Option
This feature offers the ability to disable the ALL NO YES option at arming or
disarming. When this feature is enabled, the ALL NO YES option does not display
at any system keypad during arming or disarming. Each area assigned to the user
profile is chosen to be armed or disarmed independently.
22.1.3
SVC USER AUTH
DISABLED
Service User Authentication
This feature offers the ability to authenticate service personnel before allowing
access to panel programming or performing any user operations. When this feature
is enabled and a valid Service User code is entered for system operation or 6653 is
entered for programming, the Service Code entry option displays.
When the service person enters the Service Code, the panel authenticates the code
with the Service Code preprogrammed in the SCS-1R receiver, and access to panel
programming or the User Menu is granted. The Service Code can be used for system
operation for 30 minutes before authenticating again. If the code entered is not
validated, access to programming or the User Menu using the Service User code is
denied.
Note: The Service User code is user number zero (0) and can only be created in the
panel remotely. The SCS-1R receiver must have firmware version 902 or higher to
authenticate service personnel.
Purchasing Feature Upgrades
To purchase a feature upgrade, you may contact DMP Customer Service with the
feature you would like to enable and the panel serial number. The serial number(s)
should be sent in writing via e-mail or fax. A separate feature key is issued for each
panel. The feature key only enables the requested feature on the specified panel.
The panel serial number can be located several different ways:
• Printed on a label located on the right side of the XR500 PCB.
• Using panel diagnostics. See the Appendix.
• Using Remote Link™ (version 1.18 or greater). See the Remote Link User’s
Guide (LT-0565).
— Initial Panel Connection screen
— System Information screen.