Armed short, Armed open, Disarmed short – DMP Electronics DMP Command Processor Panel XR500 User Manual
Page 81: Disarmed open, Fa series w ireless, Dmp w ireless, Fire bell, Area, Type, Xr500 series lx-bus zone information
Digital Monitoring Products
XR500 Series Canadian Programming Guide
72
APPENDIX
23.12.2 LX-Bus Zone Type Defaults
These are complete spellings of the abbreviations used for the
zone types, such as Night and Exit.
Type - These are the abbreviations used for the zone types,
such as NT and EX.
Area - For an Area or Home/Sleep/Away with Guest system
this is 1 to 32. For an All/Perimeter or Home/Sleep/Away
system, this is the Interior, Bedroom, or Perimeter. Select the
area for NT, DY, EX, A1, A2, and AR types.
Fire Bell Out - Only available for FI, FV, and SV zones. Use
any output zone number listed.
Wireless - This indicates wireless equipment is being used.
DMP Wireless - These options are for use with the DMP 1100X
Wireless Receiver.
FA Series Wireless - These options are for use with the
FA400-DMP Remote Wireless Receiver.
Message - A = alarm report, T = trouble report,
L = local, no report,
— (dash) = no report,
D = door propped (When SV zone is connected to 303 Silence/
Reset Switch), S = sensor reset/alarm silence, C = early
morning ambush cancel.
Output - These are 1 to 6 on-board and 500 to 999 off-board
relay outputs, 450 to 474 and 480 to 499 wireless outputs, D1
to D16, and G1 to G20.
Action - This selects the action of the output:
S = steady, P = pulse, M = momentary, and F = follow
Swinger - The zone can be automatically bypassed after a
programmed number of trips.
Prewarn - This selects the keypad address that sounds the
entry prewarn for this zone.
Entry Delay - This is the entry delay timer selected as the
default for this zone.
Retard Delay - Provides a programmed retard time before an
alarm initiates from a shorted zone. When used on an arming
zone, the retard delay occurs when the zone is shorted before
the armed state has changed. If the arming zone has Maintain
as the Style, the retard delay also occurs when the zone
returns to a normal state.
Presignal - Provides a keypad tone for zones in retard delay.
Retard must be YES before Presignal can be selected.
Fast Response - Provides a 167ms zone response instead of
the normal 500ms response.
Cross Zone - Provides cross zoning with any of the 574 zones.
Priority - Requires this zone to be in a normal condition
before the area can be armed.
Style - The abbreviations for arming zone style:
TGL = Toggle, ARM = Arm only, DIS = Disarm only,
STEP = Wireless arming, MNT = Maint
Style
TGL
ARM
DIS
ST
EP
MNT
TGL
*Output
Options:
1
to
6,
450
to
474,
480
to
499,
500
to
999,
D1
to
D16,
G1
to
G20.
+
=Set
retard
to
YES
before
selecting
presignal.
=Zone
functions
not
a
va
ila
bl
e.
Door Number
0
to
16
0
0
0
0
0
Real-T
ime R
eports
N
or
Y
N
N
N
N
N
Follow Area
0
to
16
0
0
0
0
Priority
N
or
Y
N
N
N
N
N
N
N
N
N
N
Cross Zone
N
or
Y
N
N
N
N
N
N
N
N
N
Fast Response
N
or
Y
N
N
N
N
N
N
N
N
N
N
Presignal
1
to
16
+
+
+
+
+
Retard Delay
N
or
Y
N
N
N
N
N
Entry Delay
1
2 3 or
4
1
Prewarn
1
to
16
1-16
Swinger
N
or
Y
Y
Y
Y
N
N
N
N
N
N
N
Armed Short
Action
S
P
M
F
S
S
S
S
S
S
S
S
S
S
Output
*
0
0
0
0
0
0
0
0
0
0
Message
A T L – D S C
A
A
A
A
A
A
A
A
A
A
Armed Open
Action
S
P
M
F
S
S
S
S
S
S
S
S
S
S
Output
*
0
0
0
0
0
0
0
0
0
0
Message
A T L – D S C
A
A
A
A
A
A
A
A
A
A
Disarmed
Short
Action
S
P
M
F
S
S
S
S
S
Output
*
0
0
0
0
0
0
0
Message
A T L – D S C
–
T
–
A
A
A
A
Disarmed
Open
Action
S
P
M
F
S
S
S
S
S
Output
*
0
0
0
0
0
Message
A T L – D S C
–
T
–
T
T
FA
Series
W
ireless
Normally Open
N
or
Y
N
N
N
N
N
N
N
N
N
N
N
End-of-Line
N
or
Y
N
N
N
N
N
N
N
N
N
N
N
INT Contact
N
or
Y
N
N
N
N
N
N
N
N
N
N
N
Check-in T
ime
None
10
30
60
60
60
60
60
60
60
60
60
60
60
60
DMP
W
ireless
1126 Sensitivity
Low
or
High
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
1126 Pulse
Count
2
or
4
4
4
4
4
4
4
4
4
4
4
4
1126 Disarm/
Disable
N
or
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
1142 LED
Operation
N
or
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Supervision Time
0
3
60
240
240
240
240
240
240
240
240
240
240
240
240
1114 Contact
1
2
3
4
1
1
1
1
1
1
1
1
1
1
1
1101 EXT
Contact N/O?
N
or
Y
N
N
N
N
N
N
N
N
N
N
N
1101 Contact
INT
or
EXT
INT
INT
INT
INT
INT
INT
INT
INT
INT
INT
INT
Wireless
N
or
Y
N
N
N
N
N
N
N
N
N
N
N
Fire Bell
Output
*
0
0
0
Area
INT
PERIM
BDRM
or
1
to
32
Type
--
NT
DY
EX
FI
PN
EM
SV
A1
A2
FV
AR
NT
DY
EX
FI
PN
EM
SV
A1
A2
FV
AR
XR500 Series LX-Bus Zone Information
Assi
gn
Di
sarm
condi
tion
for
NT
,
D
Y,
EX,
A1,
and
A2
onl
y.
Assi
gn
Pr
ew
arn
and
Entry
Del
ay
for
EX
onl
y.
Assi
gn
Retar
d
and
Pr
esi
gnal
f
or
FI,
SV
, A1,
A2,
and
PN
onl
y.
Zone T
ype
Defaults
NIGHT
D
AY
EXIT
FIRE
PANIC
EMERGENCY
SUPER
VISOR
Y
AUXILIAR
Y
1
AUXILIAR
Y
2
FIRE VERIFY
ARMING