ZONE INFORMATION

When the zone changes from normal to shorted, the programmed areas toggle between

the armed or disarmed condition using the Style programming below. When restored to

normal, no action occurs. When the zone is opened from a normal (disarmed) state, a

trouble is reported. When opened from a shorted (armed) state, an alarm is reported

and the zone is disabled until you disarm the area(s) from either a keypad or Remote

Link™ computer.
To visually indicate the armed state of the area(s), you can assign an Armed Output

to individual areas and use remote LEDs at the keyswitch. The LED turns on or off to

indicate to the user the armed state of the area(s).

ARM AREAS: PERIM

In an All/Perimeter or Home/Sleep/Away system, this option specifies the areas to

be armed by the Arming Type zone. For All/Perimeter systems, choose PERIM or ALL,

for Home/Sleep/Away or Home/Away systems, choose HOME, SLEEP, or AWAY.

PERIM ALL

Perimeter/All - Specify whether the arming zone arms just the Perimeter (PERIM) or

the Perimeter and Interior areas (ALL) for All/Perimeter systems. When disarming,

all areas are disarmed.

HOME SLEEP AWAY

Home/Sleep/Away - Specify whether the arming zone arms the Perimeter (HOME),

the Perimeter and Interior (SLEEP), or all three areas (AWAY). When disarming, all

areas are disarmed.
Arming Zone Operation

If any bad zones are present when the Arming zone is shorted, the LED delays

lighting for 5 seconds. If during the 5-second delay the Arming zone is shorted

again no arming takes place. If 5 seconds expire without the zone shorting again

or restoring to normal, the areas arm and bad zones are force armed. To allow bad

zones to be force armed, the Any Bypass option must be set to YES. If Any Bypass

option is set to NO, arming does not occur. See the Area Information - Any Bypass

section. A priority zone cannot be force armed.

19.8

STYLE:

Style

This option specifies the style for the arming/disarming operation. The default style

is TGL (toggle). Press any Select key to display the STYLE options. To view more

style options press the COMMAND key.

TGL ARM DIS STEP

TGL (Toggle) - When the zone changes from normal to shorted, the programmed

areas toggle between the armed or disarmed condition. When restored to normal,

no action occurs. When the zone opens from a normal (disarmed) state, a trouble is

reported. When opened from a shorted (armed) state, an alarm is reported and the

zone is disabled until you disarm the area(s) from either a keypad or Remote Link.
ARM - When the zone is shorted, the programmed areas are armed. When restored to

normal, no action occurs. When the zone is opened from a normal (disarmed) state, a

trouble is reported. When opened from a shorted (armed) state, an alarm is reported.
DIS (Disarm) - When programmed, a short disarms the programmed areas. When

restored to normal, no action occurs. When the zone is opened from a normal

(disarmed) state, a trouble is reported.
STEP - A short arms the areas and beeps the keypads once. A normal condition

causes no action. An open condition disarms the programmed areas and beep the

keypads for one second.
Note: This arming style is designed for wireless arming pendants. When using an

arming/disarming keyswitch locate the keyswitch within the protected area.

MNT

MNT (Maintain) - When the zone is shorted, the programmed areas are armed.

When restored to normal, the programmed areas are disarmed and any alarm bells

are silenced. When the zone is opened from a normal (disarmed) state, a trouble

is reported. If opened from a shorted (armed) state, an alarm is reported and the

zone is disabled until you disarm the area(s) from either a keypad or Remote Link.