XR500 Series Canadian Programming Guide
24
REMOTE OPTIONS
7.11.2
Encrypt Cellular Remote
YES encrypts data sent over a cellular connection. Default is NO.
7.12
Allow RS-232 Remote
YES allows remote programming over the on-board RS-232 port. Default is YES.
7.13
Entré Connection
This option displays only if the panel has network capability. Select NET to allow
a dedicated network connection with Entré. Options are NONE or NET. Default is
NONE.
7.13.1
Entré Incoming TCP Port
This option displays only if NET is chosen for the Entré connection. Enter the
programming port number for the incoming Entré connection. The programming port
identifies the port used to communicate messages to and from the Entré software.
This port cannot be the same port as programmed in Network Programming Port.
The default Programming Port setting is 2011.
7.13.2
Entré IP Address
This option displays only if NET is chosen for the Entré connection. Enter the Entré
IP address where the panel sends network messages. The Entré IP Address must be
unique and cannot be duplicated on the network. Enter all 12 digits and leave out
the periods. For example, enter IP address 192.168.0.250 as 192168000250. The
periods display automatically. Default is 0.0.0.0
7.13.3
Entré Outbound TCP Port
This option displays only if NET is chosen for the Entré connection. Enter the
programming port number for the outbound Entré connection. The programming port
identifies the port used to communicate messages to the Entré software. Default is
2001.
7.13.4
Entré Backup IP Address
This option displays only if NET is chosen for the Entré connection. Enter the IP
backup address where the panel sends network messages if the first Entré IP Address
fails. The Entré IP Address must be unique and cannot be duplicated on the network.
Enter all 12 digits and leave out the periods. For example, enter IP address
192.168.0.250 as 192168000250. The periods display automatically. Default is
0.0.0.0
7.13.5
Entré Backup TCP Port
This option displays only if NET is chosen for the Entré connection. Enter the
backup programming port number for the outbound Entré connection in case the
connection to the primary IP fails. Default is 2001.
7.13.6
Entré Checkin
Select the rate at which check-in messages are sent over the Entré connection.
Select 0 (zero) to disable check in messages. Range is 0, 3-240 minutes.
Default is 0.
7.13.7
Entré Passphrase
To enable encryption enter an 8 to 16-character Passphrase using alphanumeric
characters. If you leave the Passphrase blank, the panel communicates with Entré,
but the data is not encrypted. The Passphrase is blank by default.
7.14
Send Local Changes
This option allows the panel to automatically update Remote Link at the central
station with any changes made to the panel.
Select NET or DD to send local programming changes or User Menu changes to user
codes, user profiles, schedules, or holiday dates to Remote Link after exiting the
programming or User Menu. If NET is selected, changes are sent using Network. If
DD is selected, changes are sent using Dialer. Default is NO to disable this feature.
ENCRYPT CELL
REMOTE?
NO YES
ALLOW 232
REMOTE? NO
YES
ENTRE
CONNECTION: NONE
ENTRE INCOMING
TCP PORT: 2011
000.000.000.000
ENTRE IP
CHANGES? NO
NO NET DD
SEND LOCAL
SEND LOCAL
000.000.000.000
ENTRE BACKUP IP:
ENTRE BACKUP TCP
PORT: 2001
ENTRE CHECKIN
MINUTES: 0
ENTRE PASSPHRASE
-
ENTRE OUTBOUND
TCP PORT: 2001