16  armed output number, 17  late output number, 18  late arm delay – DMP Electronics DMP Command Processor Panel XR500 User Manual
Page 56: 19  bank safe & vault (xr500n/xr500e only), 20  common area, 21  arm first area, 22  two man rule (xr500n/xr500e only), Armed output number, Late output number, Late arm delay
XR500 Series Canadian Programming Guide
Digital Monitoring Products
47
AREA INFORMATION
18.10.1
All/Perimeter Programming
When All/Perimeter is selected as the system type, program the Interior and
Perimeter areas as needed.
18.10.2
INT
BDRM PERIM
Home/Sleep/Away Programming
When Home/Sleep/Away is selected as the system type, program the Interior,
Bedroom, and Perimeter areas as needed.
18.11
* UNUSED *
Area Name
The area name can be up to 32 alphanumeric characters. To add an area name to the
system, press any Select key and then enter up to 32 characters for the new area name.
Press COMMAND to continue. For instructions on entering alphanumeric characters see
section 1.7 Entering Alpha Characters. Inactive areas are marked * UNUSED *. Only
systems programmed for Area arming have the option available to change the area name.
To mark an active area unused, press any top row Select key to delete the old name,
then press the COMMAND key. The programmer automatically programs the name
as *UNUSED*. If you have already cleared Area Information during Initialization, all
areas are marked * UNUSED *. See Initialization section.
Home/Sleep/Away with Guest systems display the area name, but the names cannot
be changed. The following are the display names that appear on the keypad:
Area Display
Area Display
Area Display
1
Perimeter
4
Guest1 Perimeter
7
Guest2 Perimeter
2
Interior
5
Guest1 Interior
8
Guest2 Interior
3
Bedrooms
6
Guest1 Bedrooms
9
Guest2 Bedrooms
18.12
ACCOUNT NO: 12345
Account Number
Enter the account number to be sent to the receiver for this area. Choose an account
number compatible with the Communication Type selected in Communications. The
default Account Number is the one previously entered in Communications. This
account number is used when sending area messages and events to the central station.
See the Area Account Number Messages in the Appendix.
18.13
AUTO ARM NO YES
Automatic Arming
Select YES to allow this area to arm automatically according to permanent, temporary,
or extended schedules. If no schedules are programmed, the area auto arms every hour.
If closing check is selected as YES, the automatic arming function does not take
place until the expiration of a ten minute Closing Check delay. See Closing Check.
If the area has been disarmed outside of any permanent or temporary schedule, the
closing check sequence occurs one hour after the area is disarmed.
At arming, bad zones are handled according to the option selected in section Bad
Zones. If a closing report is sent, the user number is indicated as SCH on the SCS-1R
Receiver. NO disables automatic arming for this area.
18.14
BAD ZONES: BYP
Bad Zones
At the time of automatic arming, some zones in the area may not be in a normal
condition. This option allows you to program the panel response to these bad zones.
This option does not display if AUTO ARM is NO.
BYP FORC REF
BYP - All bad zones are bypassed. A report of the bypass is sent to the receiver if
Bypass Reports is YES. The report indicates SCH as the user number.
FORC - All bad zones are force armed. Zones force armed in a bad condition are
capable of restoring and reporting an alarm if tripped. A forced zone report is
transmitted if Bypass Reports is YES. The report indicates SCH as the user number.
REF - The automatic arming is refused and no arming takes place. A No Closing
report is sent to the receiver regardless of the Closing Check selection.
18.15
AUTO DIS NO YES
Automatic Disarming
NO disables automatic disarming by schedule for this area. When YES is selected,
the area automatically disarms according to permanent or temporary schedules. If
an opening report is sent to the receiver, the user number is indicated as SCH.
INT
PERIM