beautypg.com

10  door access reports, 11  supervisory reports, 12 pc log real-time status – DMP Electronics DMP Command Processor Panel XR500 User Manual

Page 52: Door access reports, Supervisory reports, Pc log real-time status, Pc log reports

background image

XR500 Series Canadian Programming Guide

Digital Monitoring Products

43

PC LOG REPORTS

PC Log Reports

17.1

PC LOG REPORTS

PC Log Reports

This section allows you to program the types of PC Log Reports the panel sends

through the 462N Network Interface Card or through the J21 Serial Connector directly

on the XR500 Series Canadian panel. The reports include information such as the type

of activity, time and date of the activity, and user name and number. These data

reports can be accessed from a PC using the Advanced Reporting Module. See the

Installation Guide (LT-0681CAN) for detailed J21 setup information or the User’s Guide

(LT-0683CAN) for more information.
Note: The network connection that sends PC Log Reports is not monitored for network

trouble. The PC Log Reports option should NOT replace the primary communication

method or act as a backup communication method.
If there is trouble with the network connection, the panel continues to attempt to

send the PC Log Reports until the connection is reestablished. The panel then sends

the reports. A Network Trouble message is

NOT sent if the connection is lost since this

report tool is not designed to be monitored by a receiver. The PC Log Reports have

the lowest priority of panel reports sent.
For information about the 462N card capabilities with PC Log Reports and Network

Communication method, see 462N Card Examples in the Appendix.
Note: The PC Log Address String entered CANNOT be the same as that entered in

Communication.

17.2

COMM TYPE: NONE

Communication Type

NONE NET 232

Select the Communication Type to send the PC Log Reports. Default is NONE.

17.3

NET IP ADDRESS

Net IP Address

This option displays when the Communication Type for PC Log Reports is NET. Enter

the IP address containing up to 16 characters. The Net IP Address must be unique and

cannot be duplicated on the network. Enter all 12 digits and leave out the periods.

For example, enter IP address 192.168.0.250 as 192168000250. The periods display

automatically.

17.4

NET PORT 2001

Net Port

This option displays when Communication Type for PC Log Reports is Net. Enter the

Port number. Valid numbers are from 0 to 65535. Default is 2001.

17.5

232 COMM PORT: O

232 Communication Port

This option displays when Communication Type for PC Log Reports is 232. To enable

PC Log Reports, select either the on-board connector (O) or select A, B, C, D or E for

the corresponding slot in use on the DMP Model 462N Network Interface card. The

slots are labeled from left to right, beginning with A. Default is O.
Set the XR500 Series panel J23 jumper to R and briefly reset the panel using the J16

jumper to activate RS-232 operation.

17.6

232 SETUP:

232 Setup

This option displays when Communication Type for PC Log Reports is 232. Enter up to

32 characters.

17.7

ARM/DIS

NO YES

Arm and Disarm Reports

Sends arming, disarming and Late to Close events. Includes the area number, name

and action, the user number and name, and the time and date.

17.8

ZONE NO YES

Zone Reports

Sends changes in the status of active zones. Includes the zone number, name, type,

the action (alarm, trouble, bypass, etc.), user number (if applicable), and area name.

For a Walk Test, Verify and Fail messages are sent for each zone.

17.9

USR CMDS NO YES

User Command Reports

Sends user code changes, schedule changes, and door access denied events.