23.6 Cross Zoning
Caution must be taken when cross zoning devices
to ensure that the Cross Zone Time is long enough
to allow an intruder to trip both devices before it
expires. A Cross Zone Time that is too short may
allow an intruder to trip the devices and allow
only a zone fault report be sent to the central
station.
When a Cross Zoned zone trips a FAULT report
is sent to the SCS-1R Receiver. When two Cross
Zoned zones trip within the Cross Zone Time, both
zones send ALARM signals to the receiver. For
example, if zones 1 and 2 are Cross Zoned zones,
and only zone 1 trips, a FAULT report is sent to
the receiver for zone 1. If zone 1 trips and zone 2
trips within the Cross Zone Time, an ALARM report
is sent to the receiver for zone 1 and zone 2.
23.7 Events Manager
The Events Manager allows you to delay sending certain reports to the central station receiver. Reports can
be kept in the panel memory until overwritten by new activity or held until the memory buffer reaches 50
events or 50 door access granted events. When the buffer is full, the panel automatically sends the stored
reports to the central station receiver. The table lists the panel reports you can delay using the Events
Manager option.
23.8 User Profiles
A profile defines the authority of each user code in the system. Profiles are programmed in the Keypad
User Menu. Several characteristics associated with each User Profile define its authority within the
system. To effectively program an XR500 Series system, you must understand the interrelationship
between profiles, devices, output groups, and areas. Below is a brief explanation of the User Profile
elements. For more information about user profiles, refer to the User Profiles Record and the XR100/
XR500 User’s Guide (LT-0683).
Note: Profiles cannot be changed via keypad in an All/Perimeter or Home/Sleep/Away system. Use the
default profiles 1 through 10.
Profile Number - Each profile may be assigned a unique number from 1 to 99.
Profile Name - Each profile may be assigned a 32-character name. The Profile Number is the default name.
Area Number - Each profile may be assigned specific areas of the system for arming and disarming.
When creating profiles 1 to 98, NO areas are assigned by default. The default for profile 99 is ALL areas
assigned. Profile 99 is preprogrammed in the system at the factory.
Access Area Number - Each profile may be assigned door access area assignments. Default for profile 1 to 98
is NO areas assigned. Default for profile 99 is ALL areas assigned. Profile 99 is preprogrammed at the factory.
Output Group Assignment - Each profile may be assigned an output group number from 1 to 10. Default
for profile 1 to 98 is NO output group assigned. Default for profile 99 is output group
10. Your system may
by programmed to turn on an output group at certain keypads when door access occurs.
User Menu Assignments - Each user profile may have any of the menus assigned to it as shown in the
following User Profile Record. The User Profile Record lists the user menu profile assignments and the
system functions users are allowed to access based on the profile numbers assigned to their codes.
Always make sure that at least one administrator in your system has a profile with
all authorities and
areas.
Report Type
Immediately Delayed
Alarm
Y
Trouble
Y
Restore
Y
Opening
Y
Closing
Y
Bypass
Y
Reset
Y
Supervisory
Y
Add Codes
Y
Delete Codes
Y
Change Codes
Y
Permanent Schedule Change
Y
Temporary Schedule Change
Y
Door Access
Y
Door Access Denied
Y
Late to Close
Y
Force Armed Zone
Y