15  bypass limit, 16  card plus pin (xr500e only), 17  house code – DMP Electronics DMP Command Processor Panel XR500 User Manual
Page 39: 18  detect wireless jamming, Bypass limit, Card plus pin (xr500e only), House code, Detect wireless jamming
Digital Monitoring Products
XR500 Series Canadian Programming Guide
30
SYSTEM OPTIONS
9.16
CARD PLUS PIN:
NO YES
Card Plus PIN (XR500E only)
Select YES to require all users to present a proximity credential and enter a PIN
number wherever user code entry is required for system functions accessed from a
keypad. Select NO to disable Card Plus PIN operation. Default is NO.
Note: The Card Plus PIN option is not designed to operate with All/Perimeter or
Home/Sleep/Away systems.
For an XR500E system using Card Plus PIN, two code entries are required by a user to
operate the system from a keypad. The first must be a code entered from a Wiegand
interface device (card, fob, etc.) using a reader such as the built-in reader of a DMP
Keypad. An external reader may also be used. The second code (User Pin) is keyed
in at the keypad or could be a second card or fob.
For a Card Plus PIN system, user codes (Card and PIN) are typically administered
using DMP System Link software.
When this option is first turned on at a keypad, the factory default (user number
9999, user code 99) must be available to enter the user menu at a keypad to then
add user codes and PIN numbers or to change existing users to add their PIN number.
If user 9999 was previously removed, re-enter this user and then set Card Plus
Pin = YES. Afterwards, user 9999 can be removed and the system only allows card
plus PIN entries.
Note: Current users of an existing system are immediately affected in that they must
have their user code information changed to add the user PIN.
9.17
WIRELESS
HOUSE CODE: 0
House Code
When using a DMP wireless system, enter a house code between 1 and 50. When
using FA Series wireless enter 99. See Wireless programming in Zone Information.
Default is 0 indicating no wireless system is being used.
The DMP house code identifies the panel, DMP receiver, and DMP transmitters to
each other. When operating, the DMP receiver listens for transmissions that have
the programmed house code and transmitter serial number.
Note: The flexibility of DMP two-way wireless operation allows an existing house
code to be changed in the panel at any time. The transmitters may take up to two
minutes to learn the new house code and continue operation.
Note: When any wireless zone programming is changed in the panel, wireless
receiver zone programming is updated. At that point, all wireless zones display as
normal for approximately 1 minute, regardless of the actual state of the zone.
9.18
DETECT WIRELESS
JAMMING: NO YES
Detect Wireless Jamming
This option displays when the House Code entered is for a DMP 1100 Series Wireless
system (1-50). When enabled and the wireless receiver detects jamming, a trouble
or alarm message displays in the Status List and is sent to the central station
receiver. Select YES to enable jamming messages to display in the Status List.
Select NO to disable jamming messages. Default is NO.
9.19
WLS AUDIBLE: DAY
WIRELESS AUDIBLE
ANY DAY MIN
Wireless Audible Annunciation
This option displays when the House Code entered is for a DMP 1100 Series Wireless
system (1-50). Press any top row key to select the keypad buzzer annunciation
method for wireless low battery and missing messages. Select ANY to enable
annunciation anytime. Select DAY to enable annunciation except during sleeping
hours (9 PM to 9 AM). Select MIN (minimum) to annunciate only Fire and Fire Verify
zones during daytime hours (9 AM to 9 PM). Default is DAY.
9.20
KEYPAD PANIC KEYS
ENABLED: NO YES
Enable Keypad Panic Keys
This option allows the two-button panic key operation selected at the keypad to
send the Panic, Emergency, or Fire message to the central station receiver. Select
YES to enable the two-button panic operation to operate. To disable the two-button
panic operation, select NO. Default is YES.
9.21
OCCUPIED
PREMISES: NO YES
Occupied Premises
For All/Perimeter or Home/Sleep/Away systems, select YES to allow the panel to
automatically disarm the interior area(s) when arming all areas and a perimeter
zone is not tripped during the exit delay. Select NO to disable this feature. Default
is YES.
Note: With a Home/Sleep/Away with Guest arming system, this feature only applies
to the main system.