smartCable or section driver Module

If a SmartCable or Section Driver Module (SDM) is present,

BoomPilot is used to set automatic section control to off/

manual , automatic or all on .
NOTE: If a SmartCable or Section Driver Module (SDM) is not

present, please refer to Single section to view example.

GPS is unavailable when the BOOMPILOT icon

is grey

. BoomPilot status bar icon will be off/

manual .

Figure 6-41: Automatic to all sections on mode

7.2

km/h

2.07

ha

> 0.0 <

A

A

Console only

To switch BoomPilot to automatic :

1. Press NAVIGATION AND GUIDANCE OPTIONS tab

to

display navigation options.

2. Press BOOMPILOT icon .

◄Automatic – status bar icon will change to green

In areas where application is not desired:

1. Press NAVIGATION AND GUIDANCE OPTIONS tab

to

display navigation options.

2. Press BOOMPILOT icon .

◄Off/manual – status bar icon will change to red

Press the BOOMPILOT icon again to resume application.

To turn all sections on :

1. Press NAVIGATION AND GUIDANCE OPTIONS tab

to

display navigation options.

2. Press and hold BOOMPILOT icon .

◄All On – Status Bar Icon will change to yellow

Matrix Pro GS Boompilot Switch Configuration

BoomPilot

(ABSC) System

Rate Controller

RC with Internal SDM

Work Switch

Spray

Icon

Master

Boom Switches

Master

Boom Switches

Automatic Mode

On

Off

On

On

Off

Manual Mode

On

On

On

On

Off

Rate controller or Switchbox

To switch BoomPilot between off/manual and automatic

when a rate controller or switchbox in on the system:

1. Turn the rate controller master switch to the “On” position.

The individual boom section switches should remain in the

“Off” position.

2. Press NAVIGATION AND GUIDANCE OPTIONS tab

to

display navigation options.

3. Press BOOMPILOT icon .

◄Automatic – status bar icon will change to green

In areas where application is not desired:

1. Press NAVIGATION AND GUIDANCE OPTIONS tab

to

display navigation options.

2. Press BOOMPILOT icon .

◄Off/manual – status bar icon will change to red

Press the BOOMPILOT icon again to resume application.
OR
1. Manually turn “off” the rate controller master switch to shut off

the booms.
◄Off/manual – status bar icon will change to red

Turn the master switch “on” to resume application.

To turn all sections on :

1. Press NAVIGATION AND GUIDANCE OPTIONS tab

to

display navigation options.

2. Press and hold BOOMPILOT icon .

◄All On – status bar icon will change to yellow

Rate controller with Internal Section Driver Module

When using a rate controller with an internal section driver

module, both the master switch and the boom section switches

need to be in the “On” position..