beautypg.com

SilentKnight 5808 User Manual

Page 150

background image

Reporting

151274-L8

9-6

Zone-based AUX1 switch trouble
restore

Trouble

UJ

1000+ Zone # 3

373

01

Zone #

Zone-based AUX2 switch trouble
restore

Trouble

UJ

2000+ Zone # 3

373

02

Zone #

Zone-based AUX1 switch trouble

Trouble

UT

1000+ Zone # 1

373

01

Zone #

Zone-based AUX2 switch trouble

Trouble

UT

2000+ Zone # 1

373

02

Zone #

Point Events

Note: Point events are reported only when “Report by Point” is selected. When
SK protocol devices are used sensors 1–99 are reported as Pnt #s 1–99, and
modules 1–99 are reported as Pnt #s 201-–299.

Auxiliary switch input disabled

Disable

pi Exp. ID

UB

Point #

1

571

Exp. ID

Point #

Auxiliary switch input re-enabled

Disable

pi Exp. ID

UU

Point #

3

571

Exp. ID

Point #

An unexpected SLC device has
been detected

Trouble

pi Exp. ID

XE

Point #

1

380

Exp. ID

Point #

An unexpected SLC device has
been removed

Trouble

pi Exp. ID

XI

Point #

3

380

Exp. ID

Point #

Auxiliary Power trouble

Trouble

pi Exp. ID

FT

Point #

1

320

Exp. ID

Point #

Aux Power trouble restore

Trouble

pi Exp. ID

FJ

Point #

3

320

Exp. ID

Point #

CO Detector Alarm

Alarm

pi Exp. ID

GA

Point #

1

162

Exp. ID

Point #

CO Detector Alarm Restore

Restore

pi Exp. ID

GH

Point #

3

162

Exp. ID

Point #

CO Detector Trouble

Trouble

pi Exp. ID

GT

Point #

1

373

Exp. ID

Point #

CO Detector Trouble Restore

Trouble

pi Exp. ID

GJ

Point #

3

373

Exp. ID

Point #

CO Supervisory Condition

Trouble

pi Exp. ID

GS

Point #

1

200

Exp. ID

Point #

CO Supervisory Condition Restore

Trouble

pi Exp. ID

GR

Point #

3

200

Exp. ID

Point #

CO Detector Input Switch Disabled

Disable

pi Exp. ID

GB

Point #

1

571

Exp. ID

Point #

CO Detector Input Switch Enabled

Disable

pi Exp. ID

GU

Point #

3

571

Exp. ID

Point #

CO Detector Disabled

Disable

pi Exp. ID

GB

Point #

1

571

Exp. ID

Point #

CO Detector Enabled

Disable

pi Exp. ID

GU

Point #

3

571

Exp. ID

Point #

Detector Alarm

Alarm

pi Exp. ID

FA

Point #

1

110

Exp. ID

Point #

Detector Alarm restore

Restore

pi Exp. ID

FH

Point #

3

110

Exp. ID

Point #

Detector Trouble

Trouble

pi Exp. ID

FT

Point #

1

373

Exp. ID

Point #

Detector Trouble restore

Trouble

pi Exp. ID

FJ

Point #

3

373

Exp. ID

Point #

Emergency Alarm # Point Alarm

1

Alarm

pi Exp. ID

QA

(EPPP) E -
Emergency #
PPP - Point #

1

220 +
Emer-
gency
#

Exp. ID

Point #

Emergency Alarm # Point Alarm Re-

store

1

Restore

pi Exp. ID

QH

(EPPP) E -
Emergency #
PPP - Point #

3

220 +
Emer-
gency
#

Exp. ID

Point #

Emergency Alarm # Point Trouble

1

Trouble

pi Exp. ID

QT

Point #

1

242

Exp. ID

Point #

Emergency Alarm # Point Trouble

Restore

1

Trouble

pi Exp. ID

QJ

Point #

3

242

Exp. ID

Point #

Emergency Alarm # Point Disabled

1

Disable

pi Exp. ID

QB

Point #

1

243

Exp. ID

Point #

Emergency Alarm # Point Enabled

1

Disable

pi Exp. ID

QU

Point #

3

243

Exp. ID

Point #

Emergency NAC Trouble

1

Trouble

pi Exp. ID

QT

Point #

1

320

Exp. ID

Point #

SIA Reporting Format

Contact ID Reporting Format

Event Description

Event

Family

Module

ID #

(if any)

SIA

Event

Code

Parameter (if

any)

Qualifier

Event

Code

Group

#

Contact

#