Chapter 6 Troubleshooting

6-2

English

ENGLISH

6

Description

Causes and solutions

Blinking

indicator(s)

• Reconnect the SL-R12D as described in “4-8 Status Display (SL-R12D)” (

➮ 4-28) in this

instruction manual.

• The SL-R12D is broken and needs to be replaced.

• If the 4-input programmable muting bank function is carried out, there is a problem with the

number of inputs from the muting devices or a problem with the timing of muting device
operation (sequence). Use the proper number of inputs and input methods as described in “2-
5-5 Four-input programmable muting bank function” (

➮ 2-14) and “4-5 Muting function” (➮ 4-

10) in this instruction manual.

• There is a loose or broken muting device wiring connection. Wiring again as described in “4-5

Muting function” (

➮ 4-10) in this instruction manual” .

• The muting device is broken and needs to be replaced.

• Reconnect the cables for the BBP unit, SL-C transmitter, and SL-C receiver as described in

“4-4 Blanking blind protection function” (

➮ 4-4) in this instruction manual.

• Reconnect the blanking blind protection unit cable and the SL-R12EX as described in
“4-4 Blanking blind protection function” (

➮ 4-4) in this instruction manual.

• The blanking blind protection unit is broken and needs to be replaced.

• Reconnect the SL-R11 and SL-R12EX as described in “3-4 Connection to the SL-U2 and the

SL-R11 Recommended Dedicated Power Supply” (

➮ 3-3).

• Either the SL-R11 or the SL-R12EX is broken and needs to be replaced.

The circuit controlling the programmable muting function is broken. Replace the SL-R12EX.

• If the 2-input programmable muting bank function is carried out, there is a problem with the

number of inputs from the muting devices. Use the proper number of inputs and input
methods as described in “2-5-4 Two-input programmable muting bank function” (

➮ 2-12) and

“4-5 Muting function” (

➮ 4-10) in this instruction manual.

• There is a loose or broken muting device wiring connection. Wiring again as described in

“4-5 Muting function” (

➮ 4-10) in this instruction manual.

• The muting device is broken and needs to be replaced.

• One or more functions have not been properly set. Configure the function(s) properly as

described in “4 Wiring and setting” (

➮ 4-1) in this instruction manual.

• The SL-R12EX's internal circuitry is malfunctioning. Replace the SL-R12EX.

9

SL-R12D error

10

Blanking blind

protection unit error

11

SL-R12EX

connection error

12

Programmable muting

bank error

13

14

Muting device

input timing error

Muting device

logic error

15

16 and others

Muting lamp error

Internal circuit error

• The program switch has been changed from the RUN to the PROG setting while the SL-

R12EX is turned ON. Turn OFF the SL-R12EX when changing the program switch setting.

• One or more functions have not been properly set. Configure the function(s) properly as

described in “Chapter 4 Wiring and setting” (

➮ 4-1) in this instruction manual.

1,3,5,7,9

11,13, and 15

Program switch error

8

MPCE error

If the MPCE monitor function is carried out, the MPCE is broken, or there is a loose or broken
wiring connection. Replace the MPCE or wiring again as appropriate in accordance with “4-3-3
Wiring to the MPCE Monitor Input Terminal” (

➮ 4-6) in the SL-R11 instruction manual.

• If a muting lamp is used, the muting lamp's bulb has burned out, or there is a loose or broken

muting lamp wiring connection. Wiring again as described in “4-5-2 Muting lamps” (

➮ 4-12) in

this instruction manual.

• The muting lamp is broken and needs to be replaced.