beautypg.com

English – KEYENCE SL-R12EX User Manual

Page 15

background image

Chapter 1 Specifications

1-7

1

ENGLISH

System

Switching type

Input power supply voltage

100 V AC to 240 V AC

±10 % (50/60 Hz)

Overvoltage category

Output voltage

24 V DC

±10 %, Class 2

2

Ripple/noise

240 mVp-p or less

Output capacity

1.8 A

Ambient temperature

-10

°C to +55 °C (non-freezing)

Relative humidity

35 % to 85 % RH (non-condensing)

Pollution degree

2

Withstand voltage

1,500 V AC, 1 min. (between all external terminals and case)

Insulation resistance

At least 50 MW (500 V DC mega, between all external terminals and case)

Supply voltage interruption

10 ms or less

Power consumption

135VA

Weight (excluding dedicated brackets) Approx. 240 g

Model

SL-U2

Environ-
ment

10 to 55 Hz, 0.7 mm (0.03") compound amplitude, 20 sweeps each in X, Y, and Z directions

100 m/s

2

, 1,000 iterations each in X, Y, and Z directions

Vibration resistance

Shock resistance

WARNING

For the power supply used for the SL-C Series, SL-R11 and SL-R12EX, always
use a power supply that can fully satisfy the above requirements or use recom-
mended SL-U2 power supply. Otherwise, the UL61496-1 requirements may not be
satisfied and the SL-C Series, SL-R11 and SL-R12EX may not be recognized as a
safety component.