4-7-3 Other indicators
(1) “CLEAR/BLOCKED” indicator
ON (GREEN)
OFF
The corresponding beam axis is clear of any obstructions.
The corresponding beam axis is being blocked.
* The beam axis with the fixed blanking function enabled will turn ON in green when it is blocked.
(2) “MODE STATUS” indicator
ON (ORANGE)
OFF
Some function of the SL-R12EX is set for the beam axes corresponding to the
indicator that turns ON. You can confirm what function(s) are set through the
“BLANKING” or “P.M.BANK “ indicators.
No function of the SL-R12EX is set for the corresponding beam axis.
(3) “BLANKING” and “P.M.BANK” indicators
“BLANKING” indicator
FIXED
FLOATING
B.B.P.
ON
(ORANGE)
ON
(ORANGE)
ON
(ORANGE)
OFF
OFF
OFF
The fixed blanking function is carried out and is set for the beam axes
corresponding to the MODE STATUS indicators that turn ON.
The fixed blanking function is not carried out, or the “Function indicator switching
button” is currently being used to check the setting status of the other functions.
The teaching floating blanking function is carried out and is set for the beam axes
corresponding to the MODE STATUS indicators that turn ON.
The teaching floating blanking function is not carried out, or the “Function indicator
switching button” is currently being used to check the setting status of the other
functions.
The blanking blind protection function is carried out and is set for the beam axes
corresponding to the MODE STATUS indicators that turn ON.
The blanking blind protection function is not carried out, or the “Function indicator
switching button” is currently being used to check the setting status of the other
functions.
“P.M.BANK” indicator
This display area's indicators will turn ON only when the programmable muting function has been
enabled.
1
2
3
ON
(ORANGE)
ON
(ORANGE)
ON
(ORANGE)
OFF
OFF
OFF
Under checking the setting status of bank 1. The muting function is set for the beam
axes corresponding to the MODE STATUS indicators that turn ON.
The programmable muting bank function is not carried out or the “Function indicator
switching button” is currently being used to check the setting status of the other
functions.
Under checking the setting status of bank 2. The muting function is set for the beam
axes corresponding to the MODE STATUS indicators that turn ON.
The programmable muting bank function is not carried out or the “Function indicator
switching button” is currently being used to check the setting status of the other
functions.
Under checking the setting status of bank 3. The muting function is set for the beam
axes corresponding to the MODE STATUS indicators that turn ON.
The programmable muting bank function is not carried out or the “Function indicator
switching button” is currently being used to check the setting status of the other
functions.
Method for switching the ”BLANKING” and “P.M.BANK” indicators
The “BLANKING” indicator or the 3 “P.M.BANK” indicator can light in the order from “BLANKING” to
“P.M.BANK 3” by pressing the function indicator switching button. Therefore, you can monitor the
information through the “MODE STATUS” indicators, which is related to the function corresponding to
the lighting indicator. These indicators light only if the corresponding function is set for the light curtain
(SL-C series).