beautypg.com

English, Warning – KEYENCE SL-R12EX User Manual

Page 49

background image

Chapter 4 Wiring and setting

4-11

4

ENGLISH

• For PNP output sensors (such as the KEYENCE PZ Series)

Sensor A1

Sensor A2

Brown

Black

Blue

Brown

Black

Blue

24 V DC

PZ, etc.

PZ, etc.

• For NPN output sensors

24 V DC

Sensor A1

Sensor A2

Brown

Black

Blue

Blue

Brown

Black

PZ, etc.

PZ, etc.

WARNING

The proper selection, usage, installation and orientation of the muting devices are
the responsibility of the employer and installer.

(4) Wiring of 4 muting devices

Wiring for the muting devices can be made only while the power to the SL-R12EX is OFF.
The following requirements must be met when making wiring connections to the SL-R12EX terminal
block.
Tightening torque: 0.4 N•m
Wire rating: AWG # 28 to 14 (Stranded only, Copper only, min. 60° C)
Cable stripping dimension:

5mm

(0.2")

• For PNP output sensors (such as the KEYENCE PZ Series)

24 V DC

Brown

Black

Brown

Black

Blue

Brown

Black

Blue

Brown

Black

Blue

Blue

Sensor A1

Sensor A2

Sensor B1

Sensor B2

PZ

etc.

PZ

etc.

PZ

etc.

PZ