Chapter 4 Wiring and setting

4-24

4

English

ENGLISH

4-6-8 Combination between the Floating blanking function, the Fixed blanking function, and the Muting function

1. Turn OFF the power to SL-R12EX and turn ON the function switch 1, and turn ON switch 2, 3 or

4. Furthermore, turn ON switch 5 for two-input muting function, or both switches 5 and 7 for
four-input muting function. Two function switches having the same number are provided on the
SL-R12EX. You must turn ON both switches. All other switches should be OFF.

No.2 is ON
No.3 is ON
No.4 is ON

Enables the floating blanking function for 1 beam axis.
Enables the floating blanking function for 2 beam axes.
Enables the floating blanking function for 3 beam axes.

2. Perform the settings according to the steps from (2) to (4) in “4-6-1 Combination between the

Floating blanking function and the Fixed blanking function” (

4-21).

4-6-9 Combining the Floating blanking function, the Blanking blind protection function, and the Muting function

1. Turn OFF the power to SL-R12EX and turn ON the function switch 8, and turn ON switch 2, 3 or

4. Furthermore, turn ON switch 5 for two-input muting function, or both switches 5 and 7 for
four-input muting function. Two function switches having the same number are provided on the
SL-R12EX. You must turn ON both switches. All other switches should be OFF.

No.2 is ON
No.3 is ON
No.4 is ON

Enables the floating blanking function for 1 beam axis.
Enables the floating blanking function for 2 beam axes.
Enables the floating blanking function for 3 beam axes.

2. Perform the settings according to the steps from (2) to (4) in “4-6-2 Combination between the

Floating blanking function and the Blanking blind protection function” (

4-21).