Chapter 4 Wiring and setting

4-20

4

English

ENGLISH

6. Press the “SET/TEACH” button once more and

release it. The P.M.BANK indicator (1, 2 or 3)
corresponding to the bank specified in Step 5 blinks.

7. Block only the beam axes by using test piece for

which you want to enable the muting function After
you have blocked the beam axes, you can confirm
that the muting function has only been set for the
intended beam axes through the status monitor
function. See “4-7 Status monitor” (

4-25) for more

information about the status monitor function. If the
muting function has been set to the other beam axes
than those intended, repeat this procedure from Step
(1).

8. Press the “SET/TEACH” button once and release it. Confirm that the “TEACHING” LED blinks

and the “P.M.BANK” LED corresponding to the bank number specified in Step (5) lights.

9. Repeat Steps (5) to (8) to set the other banks as necessary.

10.When you complete the setting procedure, turn OFF all bank switching input devices.

11.Press the “SET/TEACH” button once more and release it. Confirm that the “TEACHING” LED

turns OFF.

12.Set the PROGRAM switch to the “RUN” side.

13.The four-input programmable muting bank function can be carried out and begin operation

when you turn OFF the power to the SL-R12EX and then back ON, or when you activate restart
input on the SL-R11 (see the SL-R11 Instruction Manual for more information about restart
input).

14.See “2-5-5 Four-input Programmable muting function” (

2-14) for information about function

operation.

UNIT

BEAM

113-128

97-112

81-96

65-80

49-64

33-48

17-32

1-16

4

3

2

1

CLEAR/

BLOCKED

MODE

STATUS

BLANKING

FIXED

FLOATING

B.B.P

1

2

3

P.M.
BANK

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

P.M.BANK

Clear: the beam axes
corresponding to the
indicators lighting green.
Blocked: the beam axes
corresponding to the
indicators being OFF

The muting function is
active for the beam axes
corresponding to the
indicators lighting orange