10.When you complete the setting procedure, turn OFF all bank switching input devices.

11.Press the “SET/TEACH” button once more and release it. Confirm that the “TEACHING” LED

turns OFF.

12.Set the PROGRAM switch to the “RUN” side.

13.The two-input programmable muting bank function can be carried out and begin operation

when you turn OFF the power to the SL-R12EX and then back ON, or when you activate restart
input on the SL-R11 (see the SL-R11 Instruction Manual for more information about restart
input).

14.See “2-5-4 Two-input Programmable muting function” (

2-12) for information about function

operation.

4-5-7 Setting procedure for four-input programmable muting bank function

1. Connect the 4 muting devices, a muting lamp (such

as the SL-R12D), and the bank switching input
devices. (See “4-5-1 Muting devices” (

4-10), “4-5-2

Muting lamps” (

4-12), and “4-5-5 Bank switching

input devices” (

4-17) for more information).

2. Turn OFF the power to SL-R12EX and turn ON the

function switch 6 and 7. Two function switches
having same number are provided on the SL-R12EX.
You must turn ON both switches. All other switches
should be OFF.

3. Set the PROGRAM switch to “PROG” side.

4. Turn ON the power to the SL-R12EX and confirm that the “TEACHING” LED lights. If the

“TEACHING” LED does not light, repeat this procedure from Step (1).

5. Turn ON a single bank switching input device corresponding to the memory bank you want to

set.

SET/TEACH PROG

RUN

TEACHING

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

TEACHING

SET/TEACH

Function switches

(UP for ON; DOWN for OFF)

PROGRAM