beautypg.com

English – KEYENCE SL-R12EX User Manual

Page 26

background image

Chapter 2 Functions

2-10

2

English

ENGLISH

The following time chart shows muting function performance when it gets active in the reverse sequence
from above. This time chart also assumes sensor is used as muting devices.

Reverse direction

Sensor A1

Sensor A2

Sensor B1

Sensor B2

Muting function

Beam reception

FSD

ON

OFF

Clear

Blocked

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

(1)

(2)

(3)

5 ms

Less than 3 sec.

20 ms

Less than 3 sec.

150 ms

24 ms

Time chart explanation
(1) The muting function does not get active when the signals from the muting devices are all OFF. In other

words, the light curtain (SL-C Series) keeps normal operation. (The muting function is OFF)

(2) The muting function gets active once the signal from sensor B2 turns ON at first and the signal from

sensor B1 turns ON sequentially. At this time, the muting lamp turns ON. Further, the signal from sensor
A2 turns ON, and finally, the signal from sensor A1 turns ON. As long as the light curtain (SL-C Series)
receives the signals from the muting devices in this sequence, it keeps the muting function.

(3) If the signal from sensor B2 turns OFF, B1 turns OFF and then A2 also turns OFF sequentially after the

signals from all the sensors turn ON. The muting function cannot keep active. Therefore, the light curtain's
(SL-C Series) muting state is canceled. The muting lamp turns OFF, and the light curtain (SL-C Series)
returns to normal operation.