beautypg.com

4 power supply precautions, 4-2 recommended dedicated power supply unit, English – KEYENCE SL-R12EX User Manual

Page 14: English 1-4 power supply precautions

background image

Chapter 1 Specifications

1-6

1

English

ENGLISH

1-4 Power Supply Precautions

1-4-1 Power Units that Can Be Used as Power Supplies for SL-C Series and SL-R11/SL-R12EX

The power supply units that can be used as the power supply for SL-C Series, SL-R11 and SL-R12EX must
completely satisfy the following requirements in order to satisfy the requirements of UL61496-1 for the SL-C
Series, SL-R11, and SL-R12EX.

(a) Rated output voltage is 24V DC ±10%.
(b) The power supply to be used shall be a dedicated power supply for the SL-C Series, SL-R11 and/or SL-

R12EX and shall not be used to supply power to other devices.

(c) The power supply output must satisfy the requirements for a Class 2 Circuit or Limited Voltage/Current

Circuit as prescribed by UL508. (This requirement applies only when the SL-C Series, SL-R11 and/or SL-
R12EX is to be used in North America.)

(d) The power supply must comply with the laws, regulations, and standards covering electrical safety,

electromagnetic compatibility (EMC), etc., for the country or region in which the SL-C Series, SL-R11 and/
or SL-R12EX will be used.

(e) The output hold time is 20 ms min.

1-4-2 Recommended Dedicated Power Supply Unit

The SL-U2 is offered as the SL-C Series, SL-R11 and SL-R12EX dedicated power supply. The SL-U2 is a
power supply that completely satisfies the above requirements.

Standard No.
EN60950

Safety EN50178
standard

UL60950 (R/C)
UL508 (Listing)
EN55011 Class A

EMC standard

EN61000-6-2
FCC Part 15B Class A

SL-U2

24V DC

100 to

240 V AC

+

PE (GND)*

SL-U2

OC

+

-

N

L

CA
UTION

100-240V A

C

ONL

Y

Connection hooks

(*) The PE terminal is a protective conductor terminal that must be connected to a protective earthing

conductor in the building.