9.4 Automatic Mode
The automatic mode constantly monitors and compensates for temperature when
the accessory temperature sensor is attached to the MINI-MAX and placed on
the joint or fastener being measured. While this mode eliminates the need to
manually insert or initiate a temperature measurement, it also requires that the
user be very cautious that the sensor is properly attached to the joint or fastener,
and not accidentally removed or misplaced during the measurement process.
Selecting Automatic Temperature Mode
1) Press the
MENU key once to activate the menu items tab. Press the
MENU key multiple times to tab right, and the ESC key multiple times to
tab left, until the
UTIL menu is highlighted and displaying the submenu
items.
2) Use the
UP and DOWN arrow keys to scroll through the sub menu items
until
TEMP MODE is highlighted.
3) Use the
LEFT and RIGHT arrow keys to scroll the temperature mode
options. Once the
AUTO temperature mode is displayed.
4) Press the