Checkline TI-MINIMAX User Manual
Page 35

MINI-MAX Ultrasonic Bolt Tension Monitor
4.14 OK Key
The primary function of the
OK key is confirmation of a change or selection.
Additionally, when the loc hot menu item is selected and displaying a group, the
OK key will is also used to toggle time, elongation, load, stress, and strain
quantities.
4.15 ESC Key
The
ESC key is used in the MENU, MEAS, and EDIT functions as a back or
escape function. Additionally, when the loc hot menu item is selected and
displaying a group, the
ESC key will is also used to toggle time, elongation, load,
stress, and strain quantities.
4.16 Arrow Keys
The
Arrow Keys are used to navigate through the menus, increase/decrease
values, and toggle specific function keys.
4.17 ENTER key
The
ENTER key is used in the overall menu selection process, to activate list and
edit boxes, and save measurements to bolt group locations.
4.18 AUTO SET Key
The
AUTO SET key attempts to locate the detection of the signal or end of bolt.
This feature will only operate when an approximate length has been entered into
the MINI-MAX. This feature will prove to be very valuable, avoiding manual the
tedious process of manually trying to locate the detection point.