Setting up a bolt standard – for the first time – Checkline TI-MINIMAX User Manual
Page 55
MINI-MAX Ultrasonic Bolt Tension Monitor
Now that a bolt group has been created and material type selected to save and
document the probe zero data, this next section will go through the process of
obtaining the information needed to use the standard bolt for a probe zero
calibration bar.
Setting up a Bolt Standard – For the First Time
1) With the menu items already active, press the
MENU key multiple times
to tab right and the
ESC key multiple times to tab left until the CAL
menu is highlighted and displaying the submenu items.
2) Use the
UP and DOWN arrow keys to scroll through the sub menu items
until
ZERO MODE is highlighted.
3) Use the
LEFT and RIGHT arrow keys to scroll the zero mode options
until the
FIXED option is displayed.
Note: The fixed option sets the delay factor to zero. In other words,
disables the zero feature altogether.
4) Press the
MENU key multiple times to tab right and the ESC key
multiple times to tab left until the
MATL menu is highlighted and
displaying the submenu items.