72
Alarm Information Output
The alarm information output interface is shown as below. See Figure 3-100.
Alarm information tree: Here you can view the alarm sources of all devices.
Additional information: Here you can set the additional information when output the alarm
information. It is very useful for the peripheral devices to recognize and process the alarm.
Add: After you selected the alarm source(s) on the left panel, you can click the add butt to
add the alarm source(s). Please note when you add multiple alarm sources at the same time,
the additional information is the same.
Existed action: You can view alarm source setup here. You can check the device and set the
additional information, click the add button, you can see the corresponding action here.
Delete: After you selected an item (or items) in the existed action panel, you can remove the
setup from the list.
Alarm information output rule: Here you can set the string format of the alarm information.
Click the button
, the interface is shown as in Figure 3-101. Usually we recommend the
name such as device name+channel name+alarm information. The record type here is
invalid since it is the alarm type.
Enable other alarm type information output: Once you checked the box here, all the other
alarms (such as HDD alarm) will be output to the peripheral applications.
Additional information for other alarm type information: Here you can set the additional
information for the other alarm type.