Frequency hop table – ThingMagic M5e-Compact User Manual
Page 33
Frequency Setting
Functionality of the Embedded Modules
33
Regional Frequency Quantization
When manually setting frequencies the module will round down for any value that is not
an even multiple of the supported frequency quantization.
For example
: In the NA region, setting a frequency of 902,999 kHz results in a
setting of 902,750 kHz.
When setting the frequency of the module, any frequencies outside of the valid range for
the specified region are rejected.
Frequency Hop Table
The frequency hop table determines the frequencies used by the modules when
transmitting. The hop table characteristics are:
Contains up to 62 slots.
Valid frequencies for the region currently selected.
Changes not stored in flash, thus changes made are not retained after a power cycle
or a restart of the boot loader.
Inability to change individual entries after uploading without reloading the entire table.
Region
Frequency
Quantization
Minimum
Frequency
Maximum
Frequency
NA
250 kHz
902,000 kHz
928,000 kHz
EU
100 kHz
865,100 kHz
867,900 kHz
IN
100 kHz
865,200 kHz
866,800 kHz
EU2
50 kHz
869,000 kHz
869,850 kHz
EU3
100 kHz
865,600 kHz
867,600 kHz
KR
25 kHz
910,000 kHz
914,000 kHz
KR2
25kHz
917,300 kHz
920,300 kHz
PRC
250 kHz
920,125 kHz
924,875 kHz
AU
250kHz
920,750 kHz
925,250 kHz
NZ
250 kHz
922,250 kHz
927,250 kHz
Open
25 kHz
860,000 kHz
960,000 kHz