Get read tx power (62h), Get application commands, Set reader configuration(9ah) option data returned – ThingMagic M5e-Compact User Manual
Page 173: Field value description
![background image](/manuals/640737/173/background.png)
Get Application Commands
Command Set
173
Get Read TX Power (62h)
For deprecated version of this command see Appendix D:
The Get Read TX Power command returns the current TX power and, optionally, the
minimum and maximum power levels supported by the module (and region setting) for
reading tags, in centi-dBm.
The option field allows you to specify what data you want returned:
The following example gets the full set of power data:
The example response contains the option specified followed by 2 byte fields for each
power value:
current = 0x0BB8 = 3000 centi-dBm = 30.00 dBm
max = 0x0BB8 = 3000 centi-dBm = 30. 00 dBm
min. = 0x01F4 = 500 centi-dBm = 5.00 dBm
Repeat for all available logical antennas, as defined by the settings in
Option
Data returned
0x00
Returns only the current TX power.
0x01
Returns the current TX power and the maximum
and minimum power levels for this module.
FF
01
62
01
BE
BC
SOH
Length
OpCode
Option
CRC
FF
07
62
00
00
01
0B
B8
0B
B8
01
F4
1F
B7
SOH
Length
OpCode
Status
Option
Current centi-dBm
Max centi-dBm
Min centi-dBm
CRC