Error status codes, Clear tag buffer (2ah), Gen2 tag specific (2dh) – ThingMagic M5e-Compact User Manual
Page 119: Gen2 tag specific, 2dh), Commands as well
![background image](/manuals/640737/119/background.png)
Application Tag Commands
Command Set
119
Error Status Codes
FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h
FAULT_MSG_INVALID_PARAMETER_VALUE - 105h
FAULT_TAG_ID_BUFFER_NOT_ENOUGH_TAGS_AVAILABLE – 600h
FAULT_TAG_ID_BUFFER_NUM_TAG_TOO_LARGE – 603h
Clear Tag Buffer (2Ah)
The Clear Tag Buffer command resets the tag buffer. This clears the buffer of any
current tags and reset the read index to 0. A Read Tag Multiple
command must be
issued to load new tags into the buffer.
If Clear Tag Buffer or Get Tag Buffer is not used after a Read Tag Multiple to remove all
tags, old tags will be left in the buffer. This means that if tags that have not been removed
from the buffer are read again they will not be added to the buffer as second time, only
their Read Count will be incremented.
Error Status Codes
FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h
Gen2 Tag Specific (2Dh)
The Gen2 Tag Specific command is a generic command providing an interface for
operations proprietary to certain Gen2 tag silicon. The supported commands are grouped
by tag silicon type, indicated by the Chip Type field. Each Chip Type may have multiple
unique commands associated with it, indicated by the Sub Command field. Custom
commands for the following Chip Types are supported:
Alien Higgs Silicon (Chip Type=0x01)
Alien Higgs 3 Silicon (Chip Type=0x05)
1A
B8
CRC
FF
00
2A
1D
25
SOH
Length
OpCode
CRC