ThingMagic M5e-Compact User Manual
Page 140
![background image](/manuals/640737/140/background.png)
Application Tag Commands
140
Command Set
NXP G2i* Command Fields
An example ChangeConfig single tag command is:.
The response to the ChangeConfig command contains the new value of the tag’s
ConfigWord after the Config Data toggle bits have been appled. The format of the
Field
Value
Notes
Length
[1 byte]
OpCode
0x2D
Timeout
[2 bytes]
Ignored when used as an embedded command
for
Tag Inventory With Embedded Operations
Chip Type
0x07
0x07 - NXP G2i*
| Select Option
[1 byte]
• bit 6 (x1xx xxxx | 0x40) must be set,
indicating a 2-byte sub command follows this
byte, and before the remaining
Sub Command
[2 bytes]
• 0x0007 -
Access Password
[4 bytes]
Must be non-zero for ChangeConfig. If zero the
ConfigWord will not be changed.
| Select [Address,
Data Length, Data]
[n bytes]
Note:
Optional depending on the value of
Select Option.
RFU
0x00
RFU
Config Data
[2 bytes]
Toggle memory bits as defined by
• ‘1’ - Toggle memory bit
• ‘0’ - Leave memory alone
FF
10
2D
03
E8
07
44
00 07
11
22
33
44
00
00
00
78
08
34
SOH
Length
OpCode
Timeout (ms)
Chip
Type
Option
Sub
Cmd
Access Password
Select Data Address
Select
Length
Selct
Data
00
00
00
??
??
RFU
Config Data
CRC